Model Number FOL0101
Device Problem Disconnection (1171)
Patient Problems Skin Inflammation/ Irritation (4545); No Clinical Signs, Symptoms or Conditions (4582)
Event Date 06/04/2021
Event Type  malfunction  
Manufacturer Narrative
The investigation is still in progress.Once the investigation is complete a supplemental report will be filed.The device was not returned.
 
Event Description
It was reported that the something sticking out on the side of drain bag which was irritating the patient skin on the inner thigh.The piece sticking out was about ¼ of an inch.Per customer via phone on 03jun2021, it was sated that the port on the side of drain bag sticks up about ¼ inch and that had very sharp edges.And the customer's wife was also having the same issue with the same lot.Also stated that customer's wife used a leg bag from holister and the flat tube got kinked easily, that caused urine backed up to the bladder and leaked around the catheter.Also stated that customer's wife was using the statlock and experienced allergic to the glue being used and had to stop using and that large red area that got infected.The home care nurse was recommended bacitracin ointment from (b)(6), but it was not help much.Also recommended to use 40% zinc baby rash paste which they get from (b)(6) and that helped.Also stated that the statlock was not staying closed.
 
Manufacturer Narrative
The reported issue could be inconclusive as no sample was returned for evaluation.A potential root cause for this failure could be ¿inappropriate snap fit¿.It was unknown whether the device had met specifications.The product was used for treatment purposes.It was unknown whether the product had caused the reported failure.The device was not returned for evaluation.The device history record was reviewed and found nothing that could have caused or contributed to the reported event.The instructions for use were found adequate and state the following: "indications for use: the statlock® device is a stabilization device for compatible catheters.Contraindications: known tape or adhesive allergies.Warnings and precautions: 1.Do not use the statlock® device where loss of adherence could occur, such as with a confused patient, diaphoretic or non-adherent skin, or when the access device is not monitored daily.2.Observe universal blood and body fluid precautions and infection control procedures, during application and removal of the statlock® device.3.Minimize catheter manipulation during application and removal of the statlock® device.4.Daily maintenance: a.The statlock® device should be assessed daily and changed when clinically indicated, at least every seven days.B.If pad becomes soiled, wash with soap/water, saline or hydrogen peroxide.Do not use alcohol or prepackaged bathing systems, which could lead to early lifting.C.If showering/bathing, cover with plastic wrap or waterproof dressing.D.Conduct skin assessment prior to application and repeat daily per facility protocol.E.Use clinical judgment on the removal of the statlock® stabilization device if the patient experiences any fluid shifts that may interfere with skin integrity.Prep 1.Place foley catheter into retainer.Directional arrow should point towards catheter tip, and balloon inflation arm should be next to the clamp hinge.2.Close lid, being careful to avoid pinching the catheter.3.Identify securement site by laying the device retainer on the front of the thigh, leaving 1 inch of catheter slack between insertion site and the statlock® device retainer.4.After placing the statlock® stabilization device off to the side, cleanse and degrease the securement site with alcohol per hospital policy.Let skin dry.5.Apply skin protectant, in direction of hair growth, to area larger than securement site.Allow to dry completely (10-15 seconds).6.Using permanent marker, write initials and date of application on the statlock® device anchor pad.Note: always secure catheter into the statlock® device retainer before applying adhesive pad on skin.Place and peel 7.Align the statlock® stabilization device over securement site leaving 1 inch of catheter slack.Make sure leg is fully extended.8.While holding the retainer to keep the pad in place, peel away paper backing, one side at a time and place tension-free on skin.Removal technique disengage 1.Open retainer by pressing release button with thumb, then lift to open.2.Remove foley catheter from the statlock® device.Dissolve 3.Wipe the edge of the pad using at least 5-6 alcohol pads until a corner lifts.Then continue to stroke undersurface of pad with alcohol to dissolve adhesive pad away from skin.Do not pull or force pad to remove." h11: section a through f - the information provided by bard represents all of the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bard.H3 other text: the device was not returned.
 
Event Description
It was reported that something stuck out on the side of the drain bag which was irritating the patient¿s skin on the inner thigh.The piece sticking out was about ¼ of an inch.Also, the customer suggested this to be removed.Per customer via phone on (b)(6) 2021, it was stated that the port on the side of the drain bag stuck up about ¼ inch and had very sharp edges.And the customer's wife was also having the same issue with the same lot.Also stated that customer's wife used a leg bag from hollister.It had a flat tube and it got kinked easily.When this happened, the urine backed up to the bladder and leaked around the catheter.It was also stated that the customer's wife was using the statlock and experienced allergic to the glue being used and had to stop using them.The customer¿s wife got a large red area that got infected.The home care nurse recommended bacitracin ointment from walgreens, but that did not help much.It was also recommended to use 40% zinc baby rash paste which they got from wal-mart and that helped some.It was also stated that the statlock was not staying closed.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
SL FOLEY SWIVEL SILICONE 25BX
Type of Device
STATLOCK DEVICE
Manufacturer (Section D)
C.R. BARD, INC. (COVINGTON) -1018233
8195 industrial blvd
covington 30014
MDR Report Key12063213
MDR Text Key258297100
Report Number1018233-2021-03797
Device Sequence Number1
Product Code EYJ
UDI-Device Identifier00801741076091
UDI-Public(01)00801741076091
Combination Product (y/n)N
PMA/PMN Number
EXEMPT
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type distributor,other
Type of Report Initial,Followup
Report Date 07/21/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received06/24/2021
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Lay User/Patient
Device Expiration Date01/28/2024
Device Model NumberFOL0101
Device Catalogue NumberFOL0101
Device Lot NumberJUFP8026
Was Device Available for Evaluation? No
Date Manufacturer Received07/21/2021
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
Patient Outcome(s) Other;
-
-