Model Number 0998-00-3023-53
Device Problems Detachment of Device or Device Component (2907); Appropriate Term/Code Not Available (3191)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Date 06/14/2021
Event Type  malfunction  
Manufacturer Narrative
Testing of actual/suspected device: (10/213) the customer has been presented with the cost estimate to repair the iabp unit.Repairs are pending approval.A supplemental report will be submitted if additional information is provided.
 
Event Description
It was reported that the cs300 intra-aortic balloon pump (iabp) had a iab center input that was not staying secured.There was no patient involvement, and no adverse event reported.
 
Event Description
It was reported that prior to patient use when the cs300 intra-aortic balloon pump (iabp) was being prepared, the intra-aortic balloon (iab) center input that was not staying secured.There was no patient involvement, and no adverse event reported.
 
Manufacturer Narrative
Updated fields: b4, e2, e3, g3, g4, g7, h2, h3, h6, h10, h11.Corrected fields: h6 (medical device - problem code, investigation findings, component codes, investigation conclusions).A getinge field service engineer (fse) was dispatched to investigate.The fse evaluated the iabp unit and observed a broken fiber optic balloon connector and the connector for the balloon would not latch.The fse replaced the fiber optic assembly then verified proper fiber optic function and output.Subsequently, the fse completed all safety, functionality, and calibration checks and all tests passed to factory specifications.The iabp unit was cleared for clinical use and released to the customer.Historical data analysis: (4109/3243) the review of the historical data indicates that no other similar complaint was reported for the same serial number and reported failure mode.Trend analysis: (4110/3243) the overall 24 month product complaint trend data for the period (jul 2019 through jun 2021) was reviewed.There were no triggers identified for the review period.Analysis of production: (3331/3243) the device history records review concluded that there were no ncmrs, rework, or deviations documented for the reported serial number.Based on the dhr/lhr review results, it was determined that there is no relation between the manufacturing process and the reported failure.
 
Event Description
N/a.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
CS300
Type of Device
SYSTEM, BALLOON, INTRA-AORTIC AND CONTROL
Manufacturer (Section D)
DATASCOPE CORP. - MAHWAH
1300 macarthur blvd
mahwah NJ
MDR Report Key12137509
MDR Text Key260604763
Report Number2249723-2021-01457
Device Sequence Number1
Product Code DSP
UDI-Device Identifier10607567107882
UDI-Public10607567107882
Combination Product (y/n)N
PMA/PMN Number
K112372
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,health
Type of Report Initial,Followup,Followup
Report Date 08/04/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received07/08/2021
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Model Number0998-00-3023-53
Device Catalogue Number0998-00-3023-53
Device Lot NumberN/A
Was Device Available for Evaluation? Yes
Date Manufacturer Received08/05/2021
Patient Sequence Number1
Treatment
N/A.
-
-