SIEMENS HEALTHCARE DIAGNOSTICS, INC. ADVIA CENTAUR XPT SARS-COV-2 TOTAL (COV2T); SARS-COV-2 IMMUNOASSAY Back to Search Results
Model Number N/A
Device Problem Incorrect, Inadequate or Imprecise Result or Readings (1535)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Date 07/01/2020
Event Type  malfunction  
Manufacturer Narrative
The ifu states in the limitations section: "this assay should not be used to diagnose or exclude acute infection.Results are not intended to be used as the sole basis for patient management decisions.Test results should be interpreted in conjunction with clinical observations, patient history, epidemiological information, and other laboratory findings." a false positive/reactive result would not be used in isolation and would be correlated with clinical history.Additional laboratory testing would be used to determine specific antibody presence.A false negative/non-reactive result would be correlated with clinical history and presentation and may lead to additional testing and/or continued precautions to avoid infection with negligible clinical impact.Although there is no potential for serious injury in this case, an mdr will be reported to the fda as a requirement of the emergency use authorization (eua).Siemens healthcare diagnostics has requested clarification and is investigating.
 
Event Description
The customer observed discordant/ nonreproducible advia centaur xpt sars-cov-2 total (cov2t) results during a study for the period july 2020 to january 2021 using lot 035.The samples were tested in two replicates and reactive/nonreactive results were observed.The initial results were reported to the physician and in some cases a corrected report was issued.There are no reports of patient intervention or adverse health consequences due to the discordant cov2t results.
 
Manufacturer Narrative
Siemens filed the initial mdr 1219913-2021-00407 on august 02, 2021.(b)(6) 2021 additional information: siemens healthcare diagnostics has obtained clarification for the study for the period (b)(6) 2020 to (b)(6) 2021.The samples were tested the first time with cov2t lot 035 and the second time with cov2t lot 007 or cov2t lot 010.In the attachment "mdr 1219913-2021-00407 results attachment.Pdf" from the initial mdr, the column with the title "replicate 1" refers to the samples tested with cov2t lot 035 and the column with the title "replicate 2" refers to samples tested with cov2t lot 007 or cov2t lot 010.The customer started cov2t testing in (b)(6) 2020 with reagent lot 035 until (b)(6) 2020.For the customer, the impact study showed the discordancy of results with cov2t lot 035.Siemens healthcare diagnostics has concluded its investigation of atellica im and advia centaur sars-cov-2 total (cov2t) non-reproducible false reactive results with kit lots ending in 004, 005, 035 and 006.Siemens investigation determined that although non-reproducible false reactive results were observed with multiple kit lots, results indicate the negative percent agreement confidence interval of the kit lots evaluated overlap the confidence interval in the ifu; therefore they are performing within claims and a change in performance has not been confirmed.The ifu states in the limitations section: "this assay should not be used to diagnose or exclude acute infection.Results are not intended to be used as the sole basis for patient management decisions.Test results should be interpreted in conjunction with clinical observations, patient history, epidemiological information, and other laboratory findings.A reactive test result does not exclude past or present infection by other coronaviruses, such as sars cov-1, mers-cov, hku1, 229e, nl63, or oc43." a false positive/reactive result would not be used in isolation and would be correlated with clinical history.Additional laboratory testing would be used to determine specific antibody presence.The advia centaur xpt sars-cov-2 total (cov2t) lot 035 is performing as intended.A product performance issue has not been identified.No further evaluation of the device is required.In section h6, the investigation finding, and investigation conclusion codes were updated.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ADVIA CENTAUR XPT SARS-COV-2 TOTAL (COV2T)
Type of Device
SARS-COV-2 IMMUNOASSAY
Manufacturer (Section D)
SIEMENS HEALTHCARE DIAGNOSTICS, INC.
511 benedict avenue
tarrytown NY 10591 5097
MDR Report Key12258695
MDR Text Key264483101
Report Number1219913-2021-00407
Device Sequence Number1
Product Code QKO
Combination Product (y/n)N
PMA/PMN Number
EUA201370
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type foreign,health professional,u
Type of Report Initial,Followup
Report Date 09/15/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received08/02/2021
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Expiration Date02/22/2021
Device Model NumberN/A
Device Catalogue Number11206710
Device Lot Number035
Was Device Available for Evaluation? No
Date Manufacturer Received08/27/2021
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
-
-