Model Number 10220 |
Device Problems
Adverse Event Without Identified Device or Use Problem (2993); Appropriate Term/Code Not Available (3191)
|
Patient Problems
Electrolyte Imbalance (2196); Appropriate Clinical Signs, Symptoms, Conditions Term / Code Not Available (4581)
|
Event Date 07/17/2021 |
Event Type
Injury
|
Manufacturer Narrative
|
Lot number and expiry information are not available at this time.Investigation is in process.A follow-up report will be provided.Citation: yildirim, m., bektas, o., botan, e., sahin, s., gurbanov, a., teber, s., & kendirli, t.(2021).Therapeutic plasma exchange in clinical pediatric neurology practice: experience from a tertiary referral hospital.Clinical neurology and neurosurgery, 207, 106823.Https://doi.Org/10.1016/j.Clineuro.2021.106823.
|
|
Event Description
|
The journal article "therapeutic plasma exchange in clinical pediatric neurology practice: experience from a tertiary referral hospital" by yildirim et al 2021 was a retrospective study investigated the efficacy, tolerability, and safety of therapeutic plasma exchange (tpe) in children with neuroimmunological disorders.Twenty three patients (60.9% male, mean age = 9.4 yrs) underwent 186 tpe procedures using spectra optia apheresis system.The mean follow up was 27.1 months.No life-threatening complication occurred.Eight patients experienced complications.During the 186 tpe procedures, 13 complications occurred including hypocalcemia (n=2), hypokalemia (n=2), hypophosphatemia (n=1), anemia (n=3), thrombocytopenia (n=1), hypotension (n=2), mild edema of the eyelids and lips (n=1), and urticaria (n=1).Of the 13 complications, 11 were characterized as mild.During the follow up (mean = 27.1 months; range = 2 to 111 months), 5 patients (21.7%) died.The authors stated that ¿no mortality or long-term morbidity due to tpe occurred.¿ the results are reported in sections 3.3 and 3.6.The authors concluded that ¿tpe was found to be effective in children with various types of neuroimmunological disorder and provided an at least mild improvement in approximately 80% of the patients.Moreover, tpe was well-tolerated without life-threatening complications.The moderate complications were anemia necessitating blood transfusion and urticaria.For this event, one patient with transverse myelitis (tm) experienced hypocalcemia treated with 10% calcium gluconate intravenous infusion during the 2nd of 13 therapeutic plasma exchange (tpe) procedures performed on this patient.The disease duration prior to tpe was 9 days.The reported improvement with tpe was reported as none.The patient was reported as a exitus after follow-up in 17 months.Patient weight was not provided in the journal article.The collection set is not available for return because it was discarded by the customer.
|
|
Event Description
|
The journal article "therapeutic plasma exchange in clinical pediatric neurology practice: experience from a tertiary referral hospital" by yildirim et al 2021 was a retrospective study investigated the efficacy, tolerability, and safety of therapeutic plasma exchange (tpe) in children with neuroimmunological disorders.Twenty three patients (60.9% male, mean age = 9.4 yrs) underwent 186 tpe procedures using spectra optia apheresis system.The mean follow up was 27.1 months.No life-threatening complication occurred.Eight patients experienced complications.During the 186 tpe procedures, 13 complications occurred including hypocalcemia (n=2), hypokalemia (n=2), hypophosphatemia (n=1), anemia (n=3), thrombocytopenia (n=1), hypotension (n=2), mild edema of the eyelids and lips (n=1), and urticaria (n=1).Of the 13 complications, 11 were characterized as mild.During the follow up (mean = 27.1 months; range = 2 to 111 months), 5 patients (21.7%) died.The authors stated that ¿no mortality or long-term morbidity due to tpe occurred.¿ the results are reported in sections 3.3 and 3.6.The authors concluded that ¿tpe was found to be effective in children with various types of neuroimmunological disorder and provided an at least mild improvement in approximately 80% of the patients.Moreover, tpe was well-tolerated without life-threatening complications.The moderate complications were anemia necessitating blood transfusion and urticaria.For this event, one patient with transverse myelitis (tm) experienced hypocalcemia treated with 10% calcium gluconate intravenous infusion during the 2nd of 13 therapeutic plasma exchange (tpe) procedures performed on this patient.The disease duration prior to tpe was 9 days.The reported improvement with tpe was reported as none.The patient was reported as a exitus after follow-up in 17 months.Patient weight was not provided in the journal article.The collection set is not available for return because it was discarded by the customer.
|
|
Manufacturer Narrative
|
This report is being filed to provide additional information in h.6 and h.10.Investigation: since this was a journal publication to investigate the efficacy, tolerability, and safety of therapeutic plasma exchange (tpe) in children with neuroimmunological disorders between january 2010 and september 2020, the lot numbers were not requested; therefore, a disposable lot history search or device history record search could not be conducted.All lots must meet acceptance criteria for release.According to therapeutic apheresis: a physician's handbook, adverse events occur during therapeutic procedures with a frequency of 4.8%.Some of the most common reactions include fever, urticaria, hypocalcemic symptoms, pruritus, dyspnea, tachycardia, and mild hypotension transient hypocalcemia associated with apheresis is usually well tolerated.Symptoms often show as paresthesia (tingling) but patients may also experience unusual taste, nausea, lightheadedness, shivering, and tremors.Severe hypocalcemia may also cause muscle contractions and can progress to tetany and seizures if hypocalcemia escalates and is not corrected.According to anticoagulation techniques in apheresis: from heparin to citrate and beyond (lee, et al), several metabolic complications other than hypocalcemia have been described with citrate administration including hypomagnesemia, metabolic alkalosis, hypokalemia, and changes in parathyroid hormone levels (pth).These metabolic complications are citrate mediated and often related to citrate infusion rates or donor characteristics.Citation: yildirim, m., bektas, o., botan, e., sahin, s., gurbanov, a., teber, s., & kendirli, t.(2021).Therapeutic plasma exchange in clinical pediatric neurology practice: experience from a tertiary referral hospital.Clinical neurology and neurosurgery, 207, 106823.Https://doi.Org/10.1016/j.Clineuro.2021.106823 root cause: based on the available information a definitive root cause for the patient reactions could not be determined.Hypocalcemia occurs due to decreased ionized calcium in circulation as a result of exogenous citrate administered during the apheresis procedure and are influenced by patient physiology, the patient's disease state, the rate of ac infusion, the citrate contents in the replacement fluid, and/or the length of the procedure.These symptoms may be treated with oral or intravenous calcium supplements or by adjusting the ac infusion rate.
|
|