Model Number V60 VENT, CHINA OPT: CFLEX, AVAPS
Device Problems Volume Accuracy Problem (1675); Noise, Audible (3273)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Date 12/19/2021
Event Type  malfunction  
Event Description
At 14:43 on (b)(6) 2021, when the patient was using the ventilator, the nurse found that the tidal volume of the ventilator could not be reached all the time and found that there was an abnormal sound inside the ventilator.She immediately replaced the ventilator and reported to the equipment department for repair.After the engineer arrived at the site, he found that the blower in the pneumatic assembly made abnormal noise and was covered with dust.The engineer cleaned the dust as well as replaced the blower and filter.The device passed the self-inspection.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
RESPIRONICS
Type of Device
VENTILATOR, CONTINUOUS, MINIMAL VENTILATORY SUPPORT, FACILITY USE
Manufacturer (Section D)
RESPIRONICS CALIFORNIA, LLC
2271 cosmos court
carlsbad CA 92011
Manufacturer (Section G)
RESPIRONICS CALIFORNIA, LLC
2271 cosmos court
carlsbad CA 92011
Manufacturer Contact
melissa abbott
2271 cosmos court
carlsbad, CA 92011
7609187300
MDR Report Key13194025
MDR Text Key287344608
Report Number2031642-2022-00089
Device Sequence Number1
Product Code MNT
UDI-Device Identifier00884838025776
UDI-Public00884838025776
Combination Product (y/n)N
Reporter Country CodeCH
PMA/PMN Number
K102985
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Foreign,Health Professional
Reporter Occupation Other
Type of Report Initial
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received01/07/2022
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Model NumberV60 VENT, CHINA OPT: CFLEX, AVAPS
Device Catalogue Number1076716
Was Device Available for Evaluation? Yes
Date Manufacturer Received12/23/2021
Date Device Manufactured11/20/2014
Is the Device Single Use? No
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Reuse