Model Number ENSMS002
Device Problems Biocompatibility (2886); Patient Device Interaction Problem (4001)
Patient Problem Pressure Sores (2326)
Event Date 01/24/2022
Event Type  Injury  
Manufacturer Narrative
The investigation is still in progress.Once the investigation is complete a supplemental report will be filed.
 
Event Description
It was reported that the two dignisheild rectal tubes caused pressure injuries with the time span of six weeks therapy dates.It was unknown what medical intervention was provided for pressure injury.
 
Event Description
It was reported that the two dignishield rectal tubes caused pressure injuries with the time span of six weeks therapy dates.It was unknown what medical intervention was provided for pressure injury.
 
Manufacturer Narrative
The reported issue was inconclusive as no sample was returned for evaluation.A potential root cause for this failure could be "materials of construction are not biocompatible".It was unknown whether the device had met relevant specifications.The product was used for treatment purposes.It was unknown whether the product had caused the reported failure.The lot number was unknown; therefore, the device history record could not be reviewed.The instructions for use were found adequate and state the following: indications for use: "the bard® dignishield® stool management system(sms) winthemi¿ connector and with odor barrier properties is intended for fecal management by diverting and collecting liquid or semi-liquid stool to minimize skin contact in bedridden patients and to provide access for the administration of medications.Adult use only.Device description: the bard® dignishield® sms device withenfit¿ connector consists of a catheter tube assembly, a collection bag (figure 1), a 50 ml syringe, a syringe of lubricating jelly and a biological odor eliminator.The device has no components made of natural rubber latex.Contraindications ¿ do not use for more than 29 consecutive days.The uninterrupted use for this device, including immediate replacement with the same or an identical device, is intended to be 29 days or less.¿ do not use on patients known to be sensitive to or allergic to any components within the system.¿ do not use on patients who had lower large bowel or rectal surgery within the last year.¿ do not use on patients with any rectal or anal injury, severe rectal or anal stricture or stenosis (or on any patient if the distal rectum cannot accommodate the inflated cuff), confirmed rectal or anal tumor, severe hemorrhoids, or fecal impaction.¿ do not use on patients with suspected or confirmed rectal mucosa impairment, i.E.Severe proctitis, ischemic proctitis, mucosal ulcerations.¿ do not use on patients with indwelling rectal or anal device (e.G.Thermometer) or delivery mechanism (e.G.Suppositories) or enemas in place.Warnings ¿ there is a potential risk of misconnections with connectors from other healthcare applications, such as intravenous equipment, breathing and driving gas systems, urethral/urinary, limb cuff inflation, neuraxial devices and other enteral and gastric applications.¿ do not use if package is opened or damaged.¿ do not use improper amount or type of fluids for irrigation/flush or cuff inflations.Never use hot liquids.¿ do not over inflate retention cuff.¿ use only gravity or slow manual irrigation.Do not connect mechanical pumping devices to catheter irrigation port.Do not irrigate patient with compromised intestinal wall integrity.¿ rectal bleeding should be investigated to ensure no evidence of pressure necrosis from the device.Discontinuation of use is recommended if pressure necrosis is evident.¿ abdominal distention that occurs while using the device should be investigated.¿ prolonged traction on the catheter may result in the retention cuff migrating into the anal canal which may result in mucosal lesion, temporary or permanent clinical sphincter dysfunction, or catheter expulsion.¿ solid or soft-formed stool cannot pass through the catheter and will obstruct the opening.The use of the device is not indicated for patients with solid or soft formed stool.¿ single use only.Do not reuse.Reuse and/or packaging may create a risk possibly resulting in patient or user infection.Structural integrity and/or essential material and design characteristics of the device, may be compromised, which may lead to device failure and/or lead to injury, h11: section a through f - the information provided by bd represents all the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
BARD® DIGNISHIELD® STOOL MANAGEMENT SYSTEM WITH ENFIT¿
Type of Device
DIGNISHIELD
Manufacturer (Section D)
C.R. BARD, INC. (COVINGTON) -1018233
8195 industrial blvd
covington 30014
Manufacturer (Section G)
C.R. BARD, INC. (COVINGTON) -1018233
8195 industrial blvd
covington 30014
Manufacturer Contact
yonic anderson
8195 industrial blvd
covington 30014
7707846100
MDR Report Key13524414
MDR Text Key285556169
Report Number1018233-2022-00593
Device Sequence Number1
Product Code KNT
UDI-Device Identifier00801741113147
UDI-Public(01)00801741113147
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
K133251
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Other,Health Professional,User Facility
Reporter Occupation Physician
Type of Report Initial,Followup
Report Date 05/24/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received02/14/2022
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Device Operator Health Professional
Device Model NumberENSMS002
Device Catalogue NumberENSMS002
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Date Manufacturer Received05/24/2022
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
Patient Outcome(s) Other;
-
-