Model Number 0700615 |
Device Problem
Malposition of Device (2616)
|
Patient Problem
Pain (1994)
|
Event Date 04/25/2021 |
Event Type
Injury
|
Manufacturer Narrative
|
As the lot number for the device was not provided, a review of the device history records could not be performed.The sample was not returned to the manufacturer for inspection/evaluation.Therefore, the investigation of the reported event is inconclusive.Based upon the available information, the definitive root cause for this event is unknown.The instructions for use (ifu) is adequate for the reported device/patient code(s) and provides general instructions for use, as well as warnings, precautions and potential complications associated with the device.Upon receipt of new or additional information, a follow-up report will be submitted as applicable.
|
|
Event Description
|
It was reported through the results of a clinical trial, that post central venous catheter placement, the device was allegedly malpositioned and the team requested for repositioning of catheter.It was further reported that patient experienced neck discomfort.The current status of the patient is unknown.
|
|
Manufacturer Narrative
|
H10: as the lot number for the device was provided, a review of the device history records will be performed.The sample was not returned to the manufacturer for inspection/evaluation.Therefore, the investigation of the reported event is inconclusive.Based upon the available information, the definitive root cause for this event is unknown.The instructions for use (ifu) is adequate for the reported device/patient code(s) and provides general instructions for use, as well as warnings, precautions and potential complications associated with the device.Upon receipt of new or additional information, a follow-up report will be submitted as applicable.H10: b5, d4 (expiry date: 06/2024).H11:section a through f - the information provided by bd represents all of the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.H3 other text : device not returned.
|
|
Event Description
|
It was reported through the results of a clinical trial, that approximately three months nineteen days post central venous catheter placement procedure, the device was allegedly malpositioned.It was further reported that patient experienced neck pain due to mispositioned catheter and catheter exchange was performed.The current status of the patient was unknown.
|
|
Search Alerts/Recalls
|
|
|