Model Number DL900J |
Device Problems
Failure to Advance (2524); Device Dislodged or Dislocated (2923); Positioning Problem (3009)
|
Patient Problem
No Clinical Signs, Symptoms or Conditions (4582)
|
Event Date 03/18/2022 |
Event Type
malfunction
|
Manufacturer Narrative
|
As the lot number for the device was provided, a review of the device history records is currently being performed.The return of the sample is pending.The investigation of the reported event is currently underway.(expiry date: 02/2025).
|
|
Event Description
|
It was reported that during a jugular filter placement procedure, the device allegedly deployed in sheath.The procedure was completed using another device.There was no reported patient injury.
|
|
Event Description
|
It was reported that during a filter placement procedure, the device allegedly detached from the pusher rod and failed to advance.The procedure was completed using another device.There was no reported patient injury.
|
|
Manufacturer Narrative
|
H10: manufacturing review: a manufacturing review was not required as this is the only complaint reported to date for this product and lot.Investigation summary: one denali jugular filter kit was retuned for evaluation.The introducer sheath, filter storage tube and touhy-borst adapter were received in a connected condition.The pusher catheter was loaded within the touhy-borst adapter, filter storage tube and introducer sheath.The introducer sheath was x-rayed and it was noted that the filter was within the sheath and filter hook was disengaged from the pusher gripper.The pusher catheter was used to deploy the filter from the sheath; all limbs are present and uncrossed.Therefore, the investigation is confirmed for the device dislodged or dislocated and filter advancement issue as the filter was within the introducer sheath and filter hook was disengaged from the pusher gripper.A definitive root cause for the reported device dislodged and failure to advance issues are could not be determined based upon the provided information.Labeling review: a review of product labeling documentation (e.G., procedural instructions, indications, warnings, precautions, cautions, possible complications, contraindications, nursing guide, and unit label) did not find any product labeling inadequacy.H10: d4 (expiry date: 02/2025), g3.H11: b5, h6 (method, result).H11: section a through f ¿ the information provide by bd represents all the known information at this time.Despite good faith efforts to obtain additional information, the complainant/reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.H3 other text : see h10.
|
|
Manufacturer Narrative
|
H10: manufacturing review: a manufacturing review was not required as this is the only complaint reported to date for this product and lot.Investigation summary: the physical device was not returned for evaluation.No photos were provided for review.Therefore, the investigation is inconclusive for the reported failures as no objective evidence was provided for review.A definitive root cause for the reported device dislodged and failure to advance issues are could not be determined based upon the provided information.Labeling review: a review of product labeling documentation (e.G., procedural instructions, indications, warnings, precautions, cautions, possible complications, contraindications, nursing guide, and unit label) did not find any product labeling inadequacy.H10: d4 (expiry date: 02/2025), g3, h6 (method).H11: g1, h6 (device, result, conclusion).H11: section a through f ¿ the information provide by bd represents all the known information at this time.Despite good faith efforts to obtain additional information, the complainant/reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.H3 other text : device not returned.
|
|
Event Description
|
It was reported that during a jugular filter placement procedure, the device allegedly deployed in sheath.The procedure was completed using another device.There was no reported patient injury.
|
|