• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: OLYMPUS WINTER & IBE GMBH HF-CABLE, MONOPOLAR

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

OLYMPUS WINTER & IBE GMBH HF-CABLE, MONOPOLAR Back to Search Results
Model Number A0393
Device Problem Smoking (1585)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Type  malfunction  
Manufacturer Narrative
The device has not been returned for evaluation.If additional information becomes available prior to the conclusion of the investigation, a supplemental report will be filed.
 
Event Description
The customer reported that her olympus hf monopolar cable began smoking during procedure preparation.According to the initial reporter, the intended procedure type is unknown.However, she did confirm that the staff completed the case without any patient harm by using another cable.
 
Manufacturer Narrative
This report is being supplemented to provide additional information based on the legal manufacturer's final investigation.The device history record was unable to be reviewed for this device since the lot number was not provided.However, the manufacturing and quality control review was performed for the last 24 months of production and there are no non-conformities or deviations regarding the described issue.Based on the results of the investigation, it is very likely that the age-related wear in connection with repeated extreme bending or tensile loads most likely led to the breakage of single or all the wires in the cable.This can cause a voltage spike at the damaged area when the generator is activated which may result in a spark and complete disconnection of the plug.The specific cause of the event was likely due to age-related wear in connection with improper handling.The service life of the cable is limited to 12 months.After this time, the cable should no longer be used.The following information is stated in the instructions for use regarding proper handling of the device: "additionally, the cable must be checked for damage before each use and after reprocessing.By gently pulling on the plug (max.20nm), it can be determined whether the copper strand of the cable is already damaged.If the cable does not give way but remains rigid, the cable is most likely intact.In order not to shorten the service life of the cable any further, the cable should not be wound up with a loop diameter of less than 10cm and when pulling out the cable, the plug should be pulled and not the cable.".Olympus will continue to monitor field performance for this device.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
HF-CABLE, MONOPOLAR
Type of Device
CABLE
Manufacturer (Section D)
OLYMPUS WINTER & IBE GMBH
kuehnstrasse 61
hamburg, hamburg 22045
GM  22045
Manufacturer Contact
kazutaka matsumoto
2951 ishikawa-cho
hachioji-shi, tokyo-to 192-8-507
JA   192-8507
426425177
MDR Report Key14207934
MDR Text Key299209198
Report Number8010047-2022-07031
Device Sequence Number1
Product Code GCJ
UDI-Device Identifier04042761001656
UDI-Public04042761001656
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
K944201
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type User Facility
Reporter Occupation Non-Healthcare Professional
Type of Report Initial,Followup
Report Date 05/31/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received04/26/2022
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Model NumberA0393
Device Catalogue NumberA0393
Device Lot NumberUNKNOWN
Was Device Available for Evaluation? No
Was the Report Sent to FDA? No
Date Manufacturer Received05/02/2022
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Is the Device Single Use? No
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Reuse
Patient Sequence Number1
-
-