MAUDE Adverse Event Report: NUVASIVE, INCORPORATED NUVASIVE COROENT THORACOLUMBAR IMPLANTS; INTERVERTEBRAL FUSION DEVICE WITH BONE GRAFT, THORACIC

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

NUVASIVE, INCORPORATED NUVASIVE COROENT THORACOLUMBAR IMPLANTS; INTERVERTEBRAL FUSION DEVICE WITH BONE GRAFT, THORACIC Back to Search Results
Model Number 6308855006P2
Device Problem Fracture (1260)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Date 04/04/2022
Event Type  malfunction  
Event Description
On (b)(6) 2022 a patient underwent a extreme lateral interbody fusion procedure from l4-l6.During the procedure the spacer fractured while inserting between l5/6.The fractured piece was retrieved and a new spacer was inserted to l5/6.No patient injury or adverse consequences reported.
 
Manufacturer Narrative
No product was returned photos were provided confirming alleged incident.The root cause of the event is unknown but is likely the result of excessive off angle forces or space prep difficulties.No additional investigation can be completed.Label review: "warnings, cautions and precautions - correct selection of the implant is extremely important.The potential for success is increased by the selection of the proper size of the implant.While proper selection can minimize risks, the size and shape of human bones present limitations on the size and strength of implants." "based on fatigue testing results, when using the coroent xl interfixated system, the physician/surgeon should consider the levels of implantation." "information: to obtain a surgical technique manual or should any information regarding the products or their uses be required, please contact your local representative or nuvasive directly at (b)(4).You may also email: (b)(4)." "warnings, cautions and precautions: the subject device is intended for use only as indicated.The implantation of spinal systems should be performed only by experienced spinal surgeons with specific training in the use of this spinal system because this is a technically demanding procedure presenting a risk of serious injury to the patient.Correct selection of the implant is extremely important.The potential for success is increased by the selection of the proper size of the implant.While proper selection can minimize risks, the size and shape of human bones present limitations on the size and strength of implants.Notching, striking, and/or scratching of implants with any instrument should be avoided to reduce the risk of breakage." "compatibility: all implants should be used only with the appropriately designated instrument (reference surgical technique)." "pre-operative warnings: 5.Care should be used during surgical procedures to prevent damage to the device(s) and injury to the patient." "method of use: please refer to the surgical technique for this device." "handling of the sterile implant: open the packages carefully.Take suitable measures to ensure that the implant does not come into contact with objects that could damage its surfaces.Use only the recommended instruments for implantation of the implants.Damaged implants must not be used." "information: to obtain a surgical technique manual or should any information regarding the products or their uses be required, please contact your local representative or nuvasive directly at (b)(4).You may also email: (b)(4).This instructions for use document is intended for the us market only.For ous instructions for use, please refer to document #(b)(4) for non-sterile implants and #(b)(4) for sterile implants." (b)(4).
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
NUVASIVE COROENT THORACOLUMBAR IMPLANTS
Type of Device
INTERVERTEBRAL FUSION DEVICE WITH BONE GRAFT, THORACIC
Manufacturer (Section D)
NUVASIVE, INCORPORATED
7475 lusk boulevard
san diego CA 92121
Manufacturer (Section G)
NUVASIVE, INCORPORATED
7475 lusk boulevard
san diego CA 92121
Manufacturer Contact
geoff gannon
7475 lusk boulevard
san diego, CA 92121
MDR Report Key14575322
MDR Text Key293175065
Report Number2031966-2022-00086
Device Sequence Number1
Product Code PHM
UDI-Device Identifier00887517661166
UDI-Public887517661166
Combination Product (y/n)N
Reporter Country CodeJA
PMA/PMN Number
K150994
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Foreign,Health Professional,Company Representative
Reporter Occupation Physician
Type of Report Initial
Report Date 06/02/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received06/02/2022
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Expiration Date08/22/2023
Device Model Number6308855006P2
Device Lot NumberML1579
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Was the Report Sent to FDA? No
Date Manufacturer Received04/04/2022
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Date Device Manufactured08/23/2018
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
Patient SexMale
-
-