Model Number 1236-2-852
Device Problem Unstable (1667)
Patient Problem Joint Laxity (4526)
Event Date 08/24/2022
Event Type  Injury  
Manufacturer Narrative
Review of the device history records indicate devices were manufactured and accepted into final stock with no relevant reported discrepancies.There have been no other similar events for the lot referenced.An evaluation of the device cannot be performed as the device was not returned to the manufacturer.Should additional information become available it will be reported in a supplemental report upon completion of the investigation.The following devices were also listed in this report: cat# 626-00-46f; modular dual mobility insert; lot# 71746403 it cannot be determined which, if any of these devices may have caused or contributed to the patient's experience.
 
Event Description
It was reported that the patient's right hip was revised due to instability.The surgeon primarily wanted to revise the competitor stem to change its version, but revised the liner construct as well, partially to access the femur.An mdm metal liner and adm/ mdm poly insert were revised to a constrained liner.Rep confirmed that no further information will be released by the hospital or surgeon.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
RESTORATION ADM X3 INS 28/52
Type of Device
PROSTHESIS, HIP, SEMI-CONSTRAINED, UNCEMENTED, METAL/POLYMER, NON-POROUS, CALICU
Manufacturer (Section D)
STRYKER ORTHOPAEDICS-MAHWAH
325 corporate drive
mahwah NJ 07430
Manufacturer (Section G)
STRYKER ORTHOPAEDICS-CORK
ida industrial estate
carrigtwohill NA
EI   NA
Manufacturer Contact
joann ripoli
325 corporate drive
mahwah, NJ 07430
2018315000
MDR Report Key15436366
MDR Text Key300028033
Report Number0002249697-2022-01357
Device Sequence Number1
Product Code MEH
UDI-Device Identifier04546540638991
UDI-Public04546540638991
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
K093644
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Other,Health Professional
Reporter Occupation Physician
Type of Report Initial
Report Date 09/16/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received09/16/2022
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Device Operator Health Professional
Device Model Number1236-2-852
Device Catalogue Number1236-2-852
Device Lot Number72200201
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Date Manufacturer Received08/24/2022
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Date Device Manufactured05/19/2019
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
Patient Outcome(s) Hospitalization; Required Intervention;
Patient Age76 YR
Patient SexFemale
Patient Weight123 KG
-
-