• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: TIDI PRODUCTS SINGLE PATIENT GAIT BELT LONG; AID, TRANSFER

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

TIDI PRODUCTS SINGLE PATIENT GAIT BELT LONG; AID, TRANSFER Back to Search Results
Model Number 6556L
Device Problem Device Slipped (1584)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Type  malfunction  
Manufacturer Narrative
Summary evaluation: product has been received but evaluation of the device was not completed at the time of this report.Historical review of similar cases found that the webbing exhibited slippage or the buckle teeth was not securing the webbing if the webbing was not slipped through the buckle all the way.Using the ifu application, the webbing did not exhibit any slippage.There were several complaints received for straps slipping which were determined to be due to manufacturing issues that have been addressed via the capa system.A review of the device history record did not show any nonconformities and the device passed all product verification testing and met specifications when shipped instructions for use (ifu) were reviewed and found to provide adequate instructions and warnings for safe and effective use of the device.The instructions for use state: during the application of the belt the strap should lay flat across the buckle.Tuck excess under the belt.Always verify proper closure before use.Always check for skin integrity, proper circulation and range of motion when the belt is in use.Ensure that the belt is secure and does not compromise the patient¿s medical condition and does not interfere with tubes, lines or other equipment.All complaints are trended and reviewed by management on a monthly basis.As a part of the monthly review, any excursion above the control limits for this failure mode will be assessed, documented and acted upon as warranted.The instructions for use (ifu) were reviewed and found to provide adequate instructions and warnings for safe and effective use of the device.Manufacturer reference file (b)(4).
 
Event Description
Customer contacted us via email.The customer is returning product because it is part of lot # 1341t342 with the thinner strap material.This is a known issue and the product is being swapped on 1 for 1 basis.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
SINGLE PATIENT GAIT BELT LONG
Type of Device
AID, TRANSFER
Manufacturer (Section D)
TIDI PRODUCTS
570 enterprise drive
neenah WI
Manufacturer Contact
chris rahn
570 enterprise drive
neenah, WI 54956
9207514300
MDR Report Key15491573
MDR Text Key306360520
Report Number2182318-2022-00111
Device Sequence Number1
Product Code IKX
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
EXEMPT
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type User Facility
Reporter Occupation Other
Type of Report Initial
Report Date 08/26/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received09/27/2022
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Model Number6556L
Device Catalogue Number6556L
Device Lot Number1341T342
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer09/23/2022
Was the Report Sent to FDA? No
Date Manufacturer Received08/26/2022
Was Device Evaluated by Manufacturer? No
Date Device Manufactured12/08/2021
Is the Device Single Use? No
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Unknown
Patient Sequence Number1
-
-