• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: ALCON RESEARCH, LLC - ALCON PRECISION DEVICE PHACO TIP; UNIT, PHACOFRAGMENTATION

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

ALCON RESEARCH, LLC - ALCON PRECISION DEVICE PHACO TIP; UNIT, PHACOFRAGMENTATION Back to Search Results
Catalog Number ASKU
Device Problems Complete Blockage (1094); Particulates (1451)
Patient Problems High Blood Pressure/ Hypertension (1908); Anxiety (2328); Capsular Bag Tear (2639); Appropriate Clinical Signs, Symptoms, Conditions Term / Code Not Available (4581)
Event Date 09/12/2022
Event Type  Injury  
Manufacturer Narrative
Investigation including root cause analysis is in progress.A supplemental mdr will be filed as necessary in accordance with 21 cfr 803.56 when additional reportable information becomes available.The manufacturer internal reference number is: (b)(4).
 
Event Description
A physician reported that during a combined phacoemulsification and vitrectomy surgery for retinal detachment while using an ophthalmic console at the start of the sculpture, in the first groove in the lens, there was sudden hypothalamy (sic) with irreducible anterior incarceration /luxation of the lens.Surgeon suspect that the hypothalamy from an anterior thrust of the vitreous by increase of the patient's blood pressure.Later it was noticed that the irrigation from the console was off.Irrigation was reactivated however the patient has experienced rupture of posterior capsule (pc) and anterior capsule (ac).Followed by all these events patient had also experienced psychological traumatism and anxiety about the subsequent secondary implantation.Additional information has been requested.But none received till date.Additional information received clarified that the ophthalmic phacoemulsification (phaco) tip was also involved in the procedure, the phaco tip was clogged and a milky white solution came out of the tip.
 
Manufacturer Narrative
A sample was not received at the manufacturing site for evaluation for the report of there was hypothalamy, incarceration of the lens, posterior capsule and anterior capsule tear and the phaco tip was clogged with a white substance coming from the tip; therefore, the condition of the product could not be verified.No lot number was identified with this complaint; therefore, a device history record review could not be conducted.A sample was not received at the manufacturing site and no lot information is available, therefore, the root cause for the customer complaint issue cannot be determined.The cause of the reported event cannot be determined with the information obtained, therefore, specific action with regards to this complaint cannot be taken.Complaints are reviewed and monitored at regular intervals for any significant adverse trends.No adverse trends have been observed associated with the reported product and event.No additional action is required at this time.The manufacturer internal reference number is: (b)(4).
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
PHACO TIP
Type of Device
UNIT, PHACOFRAGMENTATION
Manufacturer (Section D)
ALCON RESEARCH, LLC - ALCON PRECISION DEVICE
714 columbia avenue
sinking spring PA 19608
Manufacturer (Section G)
ALCON RESEARCH, LLC - ALCON PRECISION DEVICE
714 columbia avenue
sinking spring PA 19608
Manufacturer Contact
jonathan schlech
6201 south freeway
mail stop ab2-6
fort worth, TX 76134
8007579780
MDR Report Key15578903
MDR Text Key301544279
Report Number2523835-2022-00374
Device Sequence Number1
Product Code HQC
Combination Product (y/n)N
Reporter Country CodeFR
PMA/PMN Number
K161794
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Foreign,Health Professional,Company Representative
Reporter Occupation Physician
Type of Report Initial,Followup
Report Date 12/29/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received10/11/2022
Is this an Adverse Event Report? No
Is this a Product Problem Report? No
Device Operator Health Professional
Device Catalogue NumberASKU
Device Lot NumberASKU
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Date Manufacturer Received12/09/2022
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
Treatment
BSS STERILE IRRIGATING SOLUTION.; CONSTELLATION SURGICAL PROCEDURE PAK.; CONSTELLATION VISION SYSTEM.
Patient Outcome(s) Other; Required Intervention;
Patient SexFemale
-
-