Model Number N/A
Device Problem Detachment of Device or Device Component (2907)
Patient Problem Failure of Implant (1924)
Event Date 10/11/2022
Event Type  Injury  
Event Description
Hold for tg it was reported that patient underwent a right hip revision approximately 5 months post implantation due to the liner dissociating from the shell.Attempts have been made and additional information on the reported event is unavailable at this time.
 
Manufacturer Narrative
(b)(4).Concomitant medical products: 110031012 ¿ vivacit bearing ¿ 65254680, 650-1055 ¿ biolox delta head ¿ 3087211, 650-1066 ¿ biolox taper ¿ 3065125, 51-104110 ¿ taperloc stem ¿ 7108762, 00625006530 ¿ bone screw ¿ j7079555, visual examination of the returned product identified there is gouging to the poly head along with indentations to the lip.The liner has scuffing visible on the inner radius and the post shows wear.Shell was not returned nor pictures provided.Review of the device history record(s) identified no deviations or anomalies during manufacturing.A definitive root cause cannot be determined.If any further information is found which would change or alter any conclusions or information, a supplemental will be filed accordingly.Zimmer biomet will continue to monitor for trends.Multiple mdr reports were filed for this event, please see associated reports: 0001825034-2022-02373.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
G7 PPS LTD ACET SHELL 56F
Type of Device
PROSTHESIS, HIP
Manufacturer (Section D)
ZIMMER BIOMET, INC.
56 e. bell drive
p.o. box 587
warsaw IN 46581
Manufacturer (Section G)
ZIMMER BIOMET, INC.
56 e. bell drive
p.o. box 587
warsaw IN 46581
Manufacturer Contact
jennifer rapsavage
56 e. bell dr.
warsaw, IN 46582
5745260384
MDR Report Key15827258
MDR Text Key303940925
Report Number0001825034-2022-02644
Device Sequence Number1
Product Code PBI
UDI-Device Identifier00880304524248
UDI-Public(01)00880304524248(17)320201(10)7185117
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
K121874
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Health Professional,Company Representative
Reporter Occupation Physician
Type of Report Initial
Report Date 11/18/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received11/18/2022
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Model NumberN/A
Device Catalogue Number010000665
Device Lot Number7185117
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Was the Report Sent to FDA? No
Date Manufacturer Received11/16/2022
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Date Device Manufactured02/01/2022
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Removal/Correction NumberN/A
Patient Sequence Number1
Patient Outcome(s) Hospitalization; Required Intervention;
Patient SexMale
-
-