• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: ASCENSION ORTHOPEDICS, INC. PIP IMPLANT; HIGH DEMAND, REVISION, SEMI-CONSTRAINED, PYROLYTIC CARBON, UNCEMENTED FINGER PRO

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

ASCENSION ORTHOPEDICS, INC. PIP IMPLANT; HIGH DEMAND, REVISION, SEMI-CONSTRAINED, PYROLYTIC CARBON, UNCEMENTED FINGER PRO Back to Search Results
Catalog Number UNKNOWN
Device Problem Adverse Event Without Identified Device or Use Problem (2993)
Patient Problem Insufficient Information (4580)
Event Date 08/20/2006
Event Type  Injury  
Event Description
It was reported that on literature review ¿long-term outcomes and duration of outdoor ambulation following primary total knee arthroplasty in patients with rheumatoid arthritis", two (2) patients had a dip fusion in the same finger where the proximal interphalangeal (pip) joint arthroplasty was performed using smith and nephew implants.It is unknown the reason for the surgery.The patients outcomes are unknown.No further information is available.
 
Manufacturer Narrative
Internal complaint reference: (b)(4).Herren, d.B., schindele, s., goldhahn, j., & simmen, b.R.(2006).Problematic bone fixation with pyrocarbon implants in proximal interphalangeal joint replacement: short-term results.Journal of hand surgery, 31(6), 643-651.Doi: 10.1016/j.Jhsb.2006.08.004.This complaint was opened by smith+nephew to document a patient complication identified through a review of clinical evidence from literature sources that includes reference to the use of a smith+nephew product.The reported issue(s) relate to known inherent procedural risks that are appropriately documented in our risk files.Smith+nephew will continue to monitor trends in accordance with our post-market surveillance process and take necessary action as required if anticipated severity and/or occurrence rates are exceeded.Smith+nephew has no reason to suspect that the product failed to meet any specifications at the time of manufacture.Based on our review of all currently available information, we are unable to confirm a relationship between the reported event and the device or identify a definitive root cause.However, as the use of our product cannot be excluded as a potential cause or contributory factor to the reported issue, we are conservatively submitting this report in accordance with applicable regulations.If additional information becomes available that alters the conclusions of this report, a follow-up report will be submitted as required.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
PIP IMPLANT
Type of Device
HIGH DEMAND, REVISION, SEMI-CONSTRAINED, PYROLYTIC CARBON, UNCEMENTED FINGER PRO
Manufacturer (Section D)
ASCENSION ORTHOPEDICS, INC.
11101 metric blvd
austin TX 78758
Manufacturer (Section G)
ASCENSION ORTHOPEDICS, INC.
11101 metric blvd
austin TX 78758
Manufacturer Contact
holly topping
7000 west william cannon drive
austin, TX 78735
5123913905
MDR Report Key15904545
MDR Text Key304688497
Report Number3002788818-2022-00156
Device Sequence Number1
Product Code OMX
Combination Product (y/n)N
Reporter Country CodeSZ
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Other,Foreign,Literature,Health Professional,Company Representative
Reporter Occupation Physician
Type of Report Initial
Report Date 12/02/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received12/02/2022
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Device Operator Health Professional
Device Catalogue NumberUNKNOWN
Device Lot NumberUNKNOWN
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Date Manufacturer Received11/24/2022
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
Patient Outcome(s) Required Intervention;
-
-