WILSON-COOK MEDICAL INC MEMORY II DOUBLE LUMEN EXTRACTION BASKET; LQR DISLODGER, STONE, BILIARY
|
Back to Search Results |
|
Catalog Number MB-35-2X4-8 |
Device Problems
Difficult to Fold, Unfold or Collapse (1254); Material Separation (1562)
|
Patient Problem
No Clinical Signs, Symptoms or Conditions (4582)
|
Event Date 10/31/2022 |
Event Type
malfunction
|
Manufacturer Narrative
|
Investigation evaluation: the product said to be involved was returned in an open pouch from the lot number provided in the report.The label matches the product returned.Our laboratory evaluation of the product said to be involved confirmed the report.The basket was fully retracted into the tubing and the handle was in the retracted position.During a functional test there was a grinding/scraping sound when the handle was manipulated with no movement from the basket.The handle was disassembled, and it was noted that the drive wire was separated from the handle with nesting of the wire inside the purple hub.For further evaluation of the drive wire cable and basket, the catheter was cut to push the drive wire cable out of the sheath.The basket was fully formed and intact.Evidence of solder was present on the handle cannula at the joint.No other anomalies were detected with the device.The device history record for the lot number said to be involved was reviewed.A discrepancy or anomaly was not observed with the product that was released for distribution.Investigation conclusion: our laboratory evaluation confirmed the report of unable to manipulate the basket.This report was due to a separation of the device in the handle.The cause of the separation is unknown.The instructions for use states: "confirm desired position of basket sheath relative to target.Advance basket out of sheath.Caution: pulling on sheath while advancing or retracting basket may damage device, rendering it inoperable." the instructions for use also indicates: "advance device through channel, in short increments, until basket sheath exits endoscope." basket deployment difficulties and buckling/breaking of the drive wire can occur if the device experiences excessive pressure.Resistance in basket movement and bends in the catheter can occur if the elevator of the endoscope is used to deflect the device at a sharp angle.Prior to distribution, all memory ii double lumen extraction baskets are subjected to a visual inspection and functional testing to ensure device integrity.A review of the device history record confirmed that the lot said to be involved met all manufacturing requirements prior to shipment.Corrective action: corrective action is not warranted at this time based on the quality engineering risk assessment.Quality assurance will continue to monitor for complaint trends and reassess the risk assessment results as post market feedback continues to become available.
|
|
Event Description
|
During cbd stone removal, the physician used a cook memory ii double lumen extraction basket.It was reported that the user pushed forward the handle and captured the stone.When the user tried to pull back the handle but it didn't move at all.The stone was out of the basket wire so she withdrew the basket out of the scope channel.Device was received (b)(6)2022 and per initial evaluation, "during function test the handle was freely moving with no movement of the basket.The handle was disassembled and the drive wire was separated from the handle with nesting in the purple hub." a section of the device did not remain inside the patient¿s body.The patient did not require any additional procedures due to this occurrence.According to the initial reporter, the patient did not experience any adverse effects due to this occurrence.
|
|
Search Alerts/Recalls
|
|
|