STRYKER NEUROVASCULAR CORK UNKNOWN_NEUROVASCULAR_PRODUCT; STENT, INTRACRANIAL NEUROVASCULAR
|
Back to Search Results |
|
Catalog Number UNK_NEU |
Device Problems
Deformation Due to Compressive Stress (2889); Adverse Event Without Identified Device or Use Problem (2993)
|
Patient Problem
Insufficient Information (4580)
|
Event Date 03/11/2019 |
Event Type
Injury
|
Event Description
|
In a study aimed to compare acute ischemic stroke (ais) patients with an occlusion of the m1 segment due to an underlying stenosis (group 1) and patients with embolic m1 occlusions without underlying stenosis (group 2) undergoing endovascular recanalization in a large-volume center in europe, a total of 533 (mean age 74 ranging from 63 to 82) consecutive acute stroke patients with an isolated m1 occlusion who underwent stent retriever mechanical thrombectomy between 02/2010 and 08/2017 were included.Underlying intracranial atherosclerotic stenosis (icas) was present in 10 patients (1.9%), whereas 523 patients (98.1%) had an embolic occlusion without stenosis.All patients underwent endovascular thrombectomy (evt) - if presence of wall irregularities in the treated vessel greater than 50% of the original vessel lumen, 2 mg nimodipine was added, 10 min later in case of regression it was considered a vasospasm, when they persisted an underlying icas was suspected.If re-occlusion occurred, the thrombectomy was repeated.When stenosis persisted, percutaneous transluminal angioplasty (pta) was performed with a non-compliant balloon.10min later when stenosis persisted or re-occlusion occurred stent implantation was performed.If thrombus formation occurred within the stent, a glycoprotein iib/iiia antagonist was slowly injected intra-arterially.Follow-up angiography was performed 10¿20 min after stent deployment and if no change or thrombus formation was observed, the procedure was terminated.Among 10 patients with icas, patient#4 presented with acute left hemiparesis; nihss 9, mr aspect score of 4, 1 retrieval attempt was made.Immediate mtici-1, dsa image after thrombectomy shows high-grade stenosis of the distal m1 segment.Dsa after stent deployment shows early re-occlusion at the proximal stent.Deployment of a second stent using the telescoping technique.Final angiogram demonstrates some contrast penetration with minimal perfusion of the mca territory (mtici 1).Follow-up cta on the following day demonstrates an occluded stent.Mrs 4 at 90 days, subject stent occluded on follow up.No further information is available.
|
|
Manufacturer Narrative
|
The device is implanted in the patient.
|
|
Event Description
|
In a study aimed to compare acute ischemic stroke (ais) patients with an occlusion of the m1 segment due to an underlying stenosis (group 1) and patients with embolic m1 occlusions without underlying stenosis (group 2) undergoing endovascular recanalization in a large-volume center in europe, a total of 533 (mean age 74 ranging from 63 to 82) consecutive acute stroke patients with an isolated m1 occlusion who underwent stent retriever mechanical thrombectomy between 02/2010 and 08/2017 were included.Underlying intracranial atherosclerotic stenosis (icas) was present in 10 patients (1.9%), whereas 523 patients (98.1%) had an embolic occlusion without stenosis.All patients underwent endovascular thrombectomy (evt) - if presence of wall irregularities in the treated vessel greater than 50% of the original vessel lumen, 2 mg nimodipine was added, 10 min later in case of regression it was considered a vasospasm, when they persisted an underlying icas was suspected.If re-occlusion occurred, the thrombectomy was repeated.When stenosis persisted, percutaneous transluminal angioplasty (pta) was performed with a non-compliant balloon.10min later when stenosis persisted or re-occlusion occurred stent implantation was performed.If thrombus formation occurred within the stent, a glycoprotein iib/iiia antagonist was slowly injected intra-arterially.Follow-up angiography was performed 10¿20 min after stent deployment and if no change or thrombus formation was observed, the procedure was terminated.Among 10 patients with icas, patient#4 presented with acute left hemiparesis; nihss 9, mr aspect score of 4, 1 retrieval attempt was made.Immediate mtici-1, dsa image after thrombectomy shows high-grade stenosis of the distal m1 segment.Dsa after stent deployment shows early re-occlusion at the proximal stent.Deployment of a second stent using the telescoping technique.Final angiogram demonstrates some contrast penetration with minimal perfusion of the mca territory (mtici 1).Follow-up cta on the following day demonstrates an occluded stent.Mrs 4 at 90 days, subject stent occluded on follow up.No further information is available.
|
|
Manufacturer Narrative
|
B1 adverse event and product problem - corrected to adverse event b2 outcomes attributed to ae - corrected to other serious (important medical events) and required intervention to prevent permanent impairment/damage f10/h6 device code grid - corrected.Although the lot number was not provided, the automated manufacturing execution system (mes) has controls in the manufacturing process to ensure the product met specifications upon release.The subject device is not available; therefore, visual testing as well as functional testing cannot be performed.It cannot be confirmed if the device met specification, as the device was not returned.The source of these complaints was from a literature article review.Good faith efforts have been exhausted in response to a request for further information.Patient vessel re-stenosis is documented in the wingspan dfu/clinical experience summary as an anticipated outcome of these types of procedures.An assignable cause of anticipated procedural complication, will be assigned to the reported patient vessel re-stenosis, as a product related root cause does not apply and the issue is due to a known physiological effect of the procedure and/or patient condition noted with the directions for use, product labeling and/or risk documentation files.
|
|