Catalog Number UNKENTERPRISE |
Device Problem
Adverse Event Without Identified Device or Use Problem (2993)
|
Patient Problems
Ischemia (1942); Thrombosis/Thrombus (4440)
|
Event Date 02/03/2023 |
Event Type
Injury
|
Manufacturer Narrative
|
Manufacturer¿s ref.No: (b)(4).This complaint is from a literature source.The following literature cite has been reviewed: qiu y, jiang l, peng s, zhu j, zhang x and xu r (2023), procedural outcome following and hemodynamic imaging analysis for anterior communicating artery wide-necked aneurysms by four different stents assisted coil embolization.Front.Phys.11:1136093.Doi: 10.3389/fphy.2023.1136093.Section d.4: the product catalog and lot numbers are not available / not reported.The unique identifier (udi) and expiration date of the device is not known.Section e.1: the initial reporter phone is not available / reported.Section h.4: the device manufacture date is not known as the device lot number is not available / not reported.Although no specific intervention is stated, it is clinically reasonable to assume an intervention would be provided in the case of an intrastent thrombosis and asymptomatic ischemia.The event is being reported to the us fda as a conservative measure.This report is being submitted pursuant to the provisions of 21 cfr, part 803.This report may be based on information which has not been investigated or verified prior to the required reporting date.This report does not reflect a conclusion by cerenovus, or its employees that the report constitutes an admission that the product, cerenovus, or its employees caused or contributed to the potential event described in this report.If information is obtained that was not available for the initial report, a follow-up report will be filed as appropriate.Missing information from this report is identified as blank; this information was not provided in the reported event or available at the time of report submission.The manufacturer will submit a supplemental report if new facts arise which materially alter information submitted in a previous mdr report.Additional information will be submitted within 30 days of receipt.
|
|
Event Description
|
This complaint is from a literature source.The following literature cite has been reviewed: qiu y, jiang l, peng s, zhu j, zhang x and xu r (2023), procedural outcome following and hemodynamic imaging analysis for anterior communicating artery wide-necked aneurysms by four different stents assisted coil embolization.Front.Phys.11:1136093.Doi: 10.3389/fphy.2023.1136093.Objective and methods: in recent years, an increasing number of scholars have suggested that the preferred treatment for wide-necked aneurysms is stent-assisted coiling (sac).The purpose of this article was to retrospectively review all consecutively treated patients who received sac for acoma aneurysms between (b)(6), and (b)(6) 2021.The authors utilized stents for several manufacturers.This compliant will capture only the results associated with the 35 cerenovus enterprise stents.The manufacturer of the coils utilized in the study are unknown.Lot, model, and catalog number are not available, but the suspected cerenovus device is possibly associated with reported adverse events: enterprise stent other cerenovus devices that were also used in this study: n/a non-cerenovus devices that were also used in this study: n/a adverse events suspected on unknown enterprise stent: 1 asymptomatic ischemia- treatment unknown.1 intrastent thrombosis- treatment unknown.
|
|
Search Alerts/Recalls
|
|