Catalog Number SEE H10. |
Device Problem
Patient Device Interaction Problem (4001)
|
Patient Problems
Cardiac Tamponade (2226); Thrombosis/Thrombus (4440); Unspecified Tissue Injury (4559)
|
Event Date 02/04/2023 |
Event Type
Injury
|
Event Description
|
This complaint is from a literature source.The following literature cite has been reviewed: dhruva ss, zhang s, chen j, noseworthy pa, doshi aa, agboola km, herrin j, jiang g, yu y, cafri g, farr kc, mbwana ms, ross js, coplan pm, drozda jp jr.Using real-world data from health systems to evaluate the safety and effectiveness of a catheter to treat ischemic ventricular tachycardia.J interv card electrophysiol.2023 feb 4.Doi: 10.1007/s10840-023-01496-x.Epub ahead of print.Pmid: 36738387.Objective/methods/study data:methods among patients undergoing ischemic vt ablation with the thermocool stsf catheter pooled across two health systems (mercy health and mayo clinic), the primary safety composite outcome of death, thromboembolic events, and procedural complications within 7 days was compared to a performance goal of 15%, which is twice the expected proportion of the primary composite safety outcome based on prior studies.The exploratory effectiveness outcome of rehospitalization for vt or heart failure or repeat vt ablation at up to 1 year was averaged across health systems among patients treated with the thermocool stsf vs.St catheters.Lot, model and catalog number are not available, but the suspected biosense device possibly associated with reported adverse events: thermocool smartouch ablation catheter and thermocool smartouch sf ablation catheter exact quantities of products cannot be accurately determined as patients can experience more than adverse event and the data is summarized.Adverse event(s) without any discussion of interventions that are possibly associated with unk_smart touch bidirectional sf: qty 1 deep venous thrombosis (deep vein thrombosis)(considered serious injury).Qty 1 pericardial effusion with hemodynamic compromise (cardiac tamponade).(recognized procedural complication).Qty 1 vascular injury (soft tissue injury) (considered serious injury).Adverse event(s) without any discussion of interventions that are possibly associated with unk_smart touch bidirectional: qty 1 vascular injury (soft tissue injury) (considered serious injury).
|
|
Manufacturer Narrative
|
Manufacture ref no.: (b)(4).This complaint is from a literature source.The following literature cite has been reviewed: dhruva ss, zhang s, chen j, noseworthy pa, doshi aa, agboola km, herrin j, jiang g, yu y, cafri g, farr kc, mbwana ms, ross js, coplan pm, drozda jp jr.Using real-world data from health systems to evaluate the safety and effectiveness of a catheter to treat ischemic ventricular tachycardia.J interv card electrophysiol.2023 feb 4.Doi: 10.1007/s10840-023-01496-x.Epub ahead of print.Pmid: 36738387.No device was received for analysis at the time of submission of the initial 3500a.Since the product was not returned for analysis, no product failure analysis can be conducted, and no determination of possible contributing factors could be made.Device history record (dhr) review cannot be conducted because the lot number was provided by the customer.This report is being submitted pursuant to the provisions of 21 cfr, part 803.This report may be based on information which has not been investigated or verified prior to the required reporting date.This report does not reflect a conclusion by biosense webster inc., or its employees that the report constitutes an admission that the product, biosense webster inc., or its employees caused or contributed to the potential event described in this report.If information is obtained that was not available for the initial report, a follow-up report will be filed as appropriate.Note: field "d4.Catalog" should be "unk_smart touch bidirectional sf".
|
|
Search Alerts/Recalls
|
|