Catalog Number 101025
Device Problem Break (1069)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Date 10/13/2023
Event Type  malfunction  
Manufacturer Narrative
Should additional relevant information become available, a supplemental report will be submitted.
 
Event Description
It was reported the arterial patient connector was observed cracked on a gambro cartridge dn prime line.When the patient arrived and was hooked up for the start of the treatment, the nurse noted that the arterial pressure on the machine was running quite high.The nurse attempted to reverse the lines on the machine's tubing to the patient catheter; however, the arterial pressures remained high.A second nurse came in to help troubleshoot and they were going to attempt to flush the patient catheter to assess if they felt any resistance that would note a clot/kink in the patient catheter that could be causing the high pressures.Once the arterial side of the machine tubing was disconnected from the patient catheter, the red lumen that helps twist on to the patient catheter "broke off" from the machine tubing and stayed on the patient catheter.They were able to remove the piece from the catheter and get it back on the tubing to be able to return the patient's blood.The treatment was ended, and a new system was set up to begin treatment with supplies.There was no report of patient injury or medical intervention associated with this event.No additional information is available.
 
Manufacturer Narrative
H10: the device was not returned and the lot number is unknown; therefore, a device analysis could not be completed.Should additional relevant information become available, a supplemental report will be submitted.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
HD CARTRIDGE LINES
Type of Device
SET, TUBING, BLOOD, WITH AND WITHOUT ANTI-REGURGITATION VALVE
Manufacturer (Section D)
BAXTER HEALTHCARE CORPORATION
deerfield IL
Manufacturer (Section G)
BAXTER HEALTHCARE - TIJUANA BAJA
blvd pacifico 10014
parque industrial pacifico
tijuana baja california CP 22 643
MX   CP 22643
Manufacturer Contact
25212 w. illinois route 120
round lake, IL 60073
2242702068
MDR Report Key18122743
MDR Text Key328037494
Report Number8030638-2023-00030
Device Sequence Number1
Product Code FJK
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
K070414
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Health Professional,Company Representative
Reporter Occupation Other
Type of Report Initial,Followup
Report Date 12/18/2023
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received11/13/2023
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Catalogue Number101025
Device Lot NumberASKU
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? No
Date Manufacturer Received12/13/2023
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
-
-