Catalog Number D134805
Device Problems Display or Visual Feedback Problem (1184); Material Puncture/Hole (1504)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Date 09/08/2023
Event Type  malfunction  
Manufacturer Narrative
The product investigation was completed.Device evaluation details: the device was returned to biosense webster (bwi) for evaluation.Visual inspection and magnetic functionality test of the returned device were performed following bwi procedures.Visual analysis of the returned sample revealed a cut on pebax with reddish-brown material inside and internal parts exposed; however, the cut could be related to the handling since in the process there are control inspection points to avoid this kind of issue; however, this could not be conclusively determined.The magnetic feature was tested, and no errors were observed.However, the blood found inside the pebax area may contribute to the issue reported by the customer.A manufacturing record evaluation was performed for the finished device 31089692l number, and no internal action was found during the review.The issue reported by the customer was confirmed.The instructions for use contain (ifu) the following recommendations: the magnetic sensor of the catheter is disconnected.If the problem persists, replace the catheter cable or the catheter.As part of biosense webster's quality process, all devices are manufactured, inspected, and released to approved specifications.This product issue will be addressed through bwi's quality system.If additional information is received regarding this event, a supplemental 3500a report will be submitted to the fda.Manufacturer's reference number: pc-(b)(4).
 
Event Description
It was reported that a patient underwent an atrial fibrillation (afib) ablation procedure with a thermocool® smart touch® sf bi-directional navigation catheter and post procedure the bwi product analysis lab identified a hole in the pebax.During the procedure, the physician stated that the bi-polar signals "looked odd".The ablating signals weren't attenuating on the distal pole but rather they were on the proximal pole instead.The physician checked the pinning configuration and double-checked that the cable in use was the correct cable.There were no errors on the carto 3 display despite the reversal of the poles.The medical team was able to proceed and finish the case despite the issue.No patient consequences were reported.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
THERMOCOOL® SMART TOUCH® SF BI-DIRECTIONAL NAVIGATION CATHETER
Type of Device
CARDIAC ABLATION PERCUTANEOUS CATHETER
Manufacturer (Section D)
BIOSENSE WEBSTER INC
31 technology drive, suite 200
irvine CA 92618
Manufacturer (Section G)
BIOSENSE WEBSTER INC (JUAREZ)
circuito interior norte
1820parque industrial salvacar
juarez 32599
MX   32599
Manufacturer Contact
kate karberg
31 technology dr
irvine, CA 92618
3035526892
MDR Report Key18252769
MDR Text Key329818110
Report Number2029046-2023-02808
Device Sequence Number1
Product Code LPB
UDI-Device Identifier10846835010183
UDI-Public10846835010183
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
P030031
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Health Professional
Reporter Occupation Other
Type of Report Initial
Report Date 12/01/2023
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received12/01/2023
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Catalogue NumberD134805
Device Lot Number31089692L
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer10/03/2023
Date Manufacturer Received11/06/2023
Was Device Evaluated by Manufacturer? Yes
Date Device Manufactured07/12/2023
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
-
-