• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: ETHICON INC. ETHILON NYLON SUTURE UNKNOWN PRODUCT; SUTURE, NONABSORBABLE

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

ETHICON INC. ETHILON NYLON SUTURE UNKNOWN PRODUCT; SUTURE, NONABSORBABLE Back to Search Results
Device Problem Adverse Event Without Identified Device or Use Problem (2993)
Patient Problems Cyst(s) (1800); Intraocular Pressure Increased (1937)
Event Date 06/21/2023
Event Type  Injury  
Manufacturer Narrative
(b)(4).This report is being submitted pursuant to the provisions of 21 cfr, part 803.This report may be based on information which has not been investigated or verified prior to the required reporting date.This report does not reflect a conclusion by ethicon inc, or its employees that the report constitutes an admission that the product, ethicon inc, or its employees caused or contributed to the potential event described in this report.If information is obtained that was not available for the initial report, a follow-up report will be filed as appropriate.Attempts are being made to obtain the following information.To date no response has been provided.If further details are received at a later date a supplemental medwatch will be sent.Does the surgeon believe that any of the ethicon products involved caused and/or contributed to the post-operative complications described in the article? which specific ethicon products have been used during the procedures (product code, lot number)? does the surgeon believe there was any deficiency with any of the ethicon products used in this procedure? if so, please provide details.Were the cases discussed in this article previously reported to ethicon? if yes, please provide a complaint reference number.Patient demographics? this report is related to a journal article; therefore, no product will be returned for analysis and the batch history records cannot be reviewed as the lot number has not been provided.H6 component code: g07002 ¿ device not returned the single complaint was reported with multiple events.There are no additional details regarding the additional events.Related events captured via 2210968-2023-10064 and 2210968-2023-10066.Citation: bmj publishing group limited 2023.Https://doi.Org/10.1136/bcr-2022-254240.
 
Event Description
Title: outcome of combined single-loop fixation of intraocular lens with ahmed glaucoma valve implantation.The aim of this study is to highlights the outcomes of single-loop fixation of iol (intraocular lens ) with agv in a post-traumatic setting and subsequent management of complications.Included in this study is a girl in late adolescence came with complaints of diminution of vision, photophobia and pain in the right eye for the past 2 months following a fire-cracker injury.Corneal traction suture was applied using 6-0 mersilk.The eyelets of the plates were fixed to the episclera using 8-0 nylon ethilon and the scleral flap was then repositioned using 6-0 polyglactin 910 vicryl and the conjunctiva was sutured using 8-0 polyglactin suture.Reported complications: increased intra ocular pressure (n-1).Tenon cyst(n-1).Conclusion: the combined approached of single- loop fixation of pciol with agv implantation is an effective procedure for rehabilitation of post traumatic open glaucoma with 180 degrees inferior capsular rim remnants and extensive conjunctival scarring.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ETHILON NYLON SUTURE UNKNOWN PRODUCT
Type of Device
SUTURE, NONABSORBABLE
Manufacturer (Section D)
ETHICON INC.
1000 route 202
raritan NJ 08869
Manufacturer (Section G)
ETHICON INC.
Manufacturer Contact
elba bello
1000 route 202
raritan, NJ 08869
9083863534
MDR Report Key18382672
MDR Text Key331184658
Report Number2210968-2023-10065
Device Sequence Number1
Product Code GAR
Combination Product (y/n)N
Reporter Country CodeIN
PMA/PMN Number
NA
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Foreign,Literature,Health Professional
Reporter Occupation Other
Type of Report Initial,Followup
Report Date 01/02/2024
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received12/22/2023
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Device Operator Health Professional
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? No
Date Manufacturer Received12/22/2023
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
Patient Outcome(s) Required Intervention;
-
-