SISTEMAS MEDICOS ALARIS S.A. DE C.V. UNSPECIFIED BD INFUSION SET; INTRAVASCULAR ADMINISTRATION SET Back to Search Results
Catalog Number UNKNOWN
Device Problem Pressure Problem (3012)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Date 01/04/2024
Event Type  malfunction  
Manufacturer Narrative
H.3.If a device evaluation and/or device history review is completed, a supplemental report will be filed.
 
Event Description
It was reported that unspecified bd infusion set tubing expands the following information was received by the initial reporter with the following verbatim: typically, the issue occurs when excessive pressures are allowed to reach the pumping chamber.E.G., if someone administers an iv push but does not clamp above the smartsite.The attached tip sheet is not in circulation anymore, but for your reference, it talks about this in the faq section.
 
Event Description
No additional info.
 
Manufacturer Narrative
The customer reported that there was a bulge in the silicone segment.One photo was taken by the customer that verifies the complaint.Although a sample was not received, the probable root cause for the failure is determined to be a user issue.If the infusion set is not loaded correctly, a ballooning in the pumping segment tubing is possible.The clinical team has been made aware of the issue and the issue has been communicated with the customer with additional instructional material for proper loading of the alaris pumps.A device history record review could not be performed because a model and lot number was not provided by the customer.This incident has been added to our database of reported incidents.Our business team regularly reviews the collected data for identification of emerging trends.Your assistance in this matter has been helpful in trend identification and supporting our commitment to continuous quality improvement.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
UNSPECIFIED BD INFUSION SET
Type of Device
INTRAVASCULAR ADMINISTRATION SET
Manufacturer (Section D)
SISTEMAS MEDICOS ALARIS S.A. DE C.V.
blvd. insurgentes no. 20351
parque industrial el florido
tijuana
Manufacturer (Section G)
SISTEMAS MEDICOS ALARIS S.A. DE C.V.
blvd. insurgentes no. 20351
parque industrial el florido
tijuana
Manufacturer Contact
helen cox (mdr)
75 north fairway drive
vernon hills, IL 60061
8473935694
MDR Report Key18531711
MDR Text Key333373294
Report Number9616066-2024-00017
Device Sequence Number1
Product Code FPA
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
NA
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type User Facility
Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup
Report Date 02/12/2024
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received01/17/2024
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Other
Device Catalogue NumberUNKNOWN
Device Lot NumberUNKNOWN
Is the Reporter a Health Professional? Yes
Date Manufacturer Received02/12/2024
Was Device Evaluated by Manufacturer? Yes
Is the Device Single Use? Yes
Type of Device Usage Initial
Patient Sequence Number1
-
-