MAUDE Adverse Event Report: ABBOTT VASCULAR EMBOSHIELD NAV6 EMBOLIC PROTECTION SYSTEM

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

ABBOTT VASCULAR EMBOSHIELD NAV6 EMBOLIC PROTECTION SYSTEM Back to Search Results
Catalog Number 22437-19
Device Problems Break (1069); Difficult to Insert (1316); Stretched (1601); Material Twisted/Bent (2981)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Date 12/30/2023
Event Type  malfunction  
Manufacturer Narrative
Manufacturer's investigation is still pending at this time.Results and conclusions will be provided in the final report.
 
Event Description
It was reported that during preparation of the emboshield nav 6 embolic protection system (eps), when loading the filtration element into the delivery catheter (dc) pod with the torque device, the tip of the bare wire was noted to be unraveling thus prevented the filtration element from being loaded into the dc pod.Bunching and wrinkling was observed on the dc pod during loading but was not noted prior to loading.The eps device was not used.A new emboshield nav6 eps was used to complete the procedure.There was no patient involvement and no clinically significant delay in the procedure.No additional information was provided.
 
Manufacturer Narrative
Visual, dimensional, and functional analysis was performed on the returned device.The reported damage to the barewire and dc pod was confirmed.The reported difficult to insert was unable to be confirmed due to the condition of the returned delivery catheter and barewire; however, functional testing with returned filter and proxy delivery catheter and barewire were successful.A review of the lot history record identified no manufacturing nonconformities issued to the reported lot that would have contributed to this event.Additionally, a review of the complaint history revealed no indication of a lot specific product quality issue.The investigation was unable to determine a conclusive cause for the reported difficulty.It may be possible that the filter was pulled into the pod too quickly or with excessive force causing the noted damage to the delivery catheter pod, damage to the barewire tip and difficulty loading the filtration element; however, this could not be confirmed.There is no indication of a product quality issue with respect to the design, manufacture, or labeling.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
EMBOSHIELD NAV6 EMBOLIC PROTECTION SYSTEM
Type of Device
EMBOLIC PROTECTION SYSTEM
Manufacturer (Section D)
ABBOTT VASCULAR
26531 ynez rd.
temecula CA 92591 4628
Manufacturer (Section G)
ABBOTT VASCULAR, REG # 2024168
26531 ynez road
temecula CA 92591 4628
Manufacturer Contact
lindsey bell
26531 ynez rd.
temecula, CA 92591-4628
9519143996
MDR Report Key18543639
MDR Text Key333252960
Report Number2024168-2024-00987
Device Sequence Number1
Product Code NTE
UDI-Device Identifier08717648137747
UDI-Public08717648137747
Combination Product (y/n)N
Reporter Country CodeCH
PMA/PMN Number
K141678
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Foreign,Health Professional,Company Representative,Distributor
Reporter Occupation Physician
Type of Report Initial,Followup
Report Date 03/20/2024
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received01/19/2024
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Catalogue Number22437-19
Device Lot Number1121761
Was Device Available for Evaluation? Device Returned to Manufacturer
Is the Reporter a Health Professional? Yes
Date Manufacturer Received03/04/2024
Was Device Evaluated by Manufacturer? Yes
Date Device Manufactured12/17/2021
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
-
-