MEDTRONIC NEUROSURGERY STRATA®; SHUNT, CENTRAL NERVOUS SYSTEM AND COMPONENTS Back to Search Results
Model Number UNKNOWN-S
Device Problem Adverse Event Without Identified Device or Use Problem (2993)
Patient Problems Headache (1880); Paralysis (1997); Visual Impairment (2138); Dysphasia (2195); Cognitive Changes (2551); Convulsion/Seizure (4406)
Event Date 03/22/2022
Event Type  Injury  
Event Description
H.Westley phillips, cassia a.B.Maniquis, jia-shu chen, shannon l.Duby, yasunori nagahama, david bergeron, george m.Ibrahim, alexander g.Weil, aria fallah.Midline brain shift after hemispheric surgery: natural history, clinical significance, and association with cerebrospinal fluid diversion.Operative neurosurgery 22 (2022).Doi: 10.1227/ons.0000000000000134.Background: hemispherectomy and its modern variants are effective surgical treatments for medically intractable unihemispheric epilepsy.Although some complications such as posthemorrhoidectomy hydrocephalus are well documented, midline brain shift (mlbs) after hemispheric surgery has only been described anecdotally and never formally studied.Objective: to assess the natural history and clinical relevance of mlbs and determine whether cerebrospinal fluid (csf) shunting of the ipsilateral surgical cavity exacerbates mlbs posthemispheric surgery.Methods: a retrospective review of consecutive pediatric patients who underwent hemispheric surgery for intractable epilepsy and at least 6 months of follow-up at ucla between 1994 and 2018 was performed.Patients were grouped by mlbs severity, shunt placement, valve type, and valve opening pressure (vop).Mlbs was evaluated using the paired samples t-test and analysis of covariance adjusting for follow-up time and baseline postoperative mlbs.Results: seventy patients were analyzed, of which 23 (33%) required csf shunt placement in the ipsilateral surgical cavity for posthemispherectomy hydrocephalus.Mlbs increased between first and last follow-up for nonshunted (5.3 ± 4.9-9.7 ± 6.6 mm, p <(><<)>.001) and shunted (6.6 ± 3.5-16.3 ± 9.4 mm, p <(><<)>.001) patients.Mlbs progression was greater in shunted patients (p =.001).Shunts with higher vops did not increase mlbs relative to nonshunted patients (p =.834), whereas mlbs increased with lower vops (p =.001).Severe mlbs was associated with debilitating headaches (p =.048).Conclusion: patients undergoing hemispheric surgery often develop postoperative mlbs, ie, exacerbated by csf shunting of the ipsilateral surgical cavity, specifically when using lower vop settings.Mlbs exacerbation may be related to overshunting.Severe mlbs is associated with debilitating headaches.Reported events: - mlbs was exacerbated by csf shunting where patients experienced the following mild or severe clinical symptoms: language deficits, motor deficits, sensory deficits, visual deficits, cranial nerve palsies, metabolic/endocrine abnormalities, behavior changes, headaches, persistent/recurrent seizures, and others.See attached literature article.
 
Manufacturer Narrative
Medtronic is submitting this report to comply with fda reporting regulations under 21 cfr parts 4 and 803.This report is based upon information obtained by medtronic, which the company may not have been able to fully investigate or verify prior to the date the report was required by the fda.Medtronic has made reasonable efforts to obtain more complete information and has provided as much relevant information as is available to the company as of the submission date of this report.This report does not constitute an admission or a conclusion by fda, medtronic, or its employees that the device, medtronic, or its employee caused or contributed to the event described in the report.In particular, this report does not constitute an admission by anyone that the product described in this report has any ¿defects¿ or has ¿malfunctioned¿.These words are included in the fda 3500a form and are fixed items for selection created by the fda to categorize the type of event solely for the purpose of regulatory reporting.Medtronic objects to the use of these words and others like them because of the lack of definition and the connotations implied by these terms.This statement should be included with any information or report disclosed to the public under the freedom of information act.Any required fields that are unpopulated are blank because the information is currently unknown or unavailable.A good faith effort will be made to obtain the applicable information relevant to the report.If information is provided in the future, a supplemental report will be issued.
 
Manufacturer Narrative
Medtronic is submitting this report to comply with fda reporting regulations under 21 cfr parts 4 and 803.This report is based upon information obtained by medtronic, which the company may not have been able to fully investigate or verify prior to the date the report was required by the fda.Medtronic has made reasonable efforts to obtain more complete information and has provided as much relevant information as is available to the company as of the submission date of this report.This report does not constitute an admission or a conclusion by fda, medtronic, or its employees that the device, medtronic, or its employee caused or contributed to the event described in the report.In particular, this report does not constitute an admission by anyone that the product described in this report has any ¿defects¿ or has ¿malfunctioned¿.These words are included in the fda 3500a form and are fixed items for selection created by the fda to categorize the type of event solely for the purpose of regulatory reporting.Medtronic objects to the use of these words and others like them because of the lack of definition and the connotations implied by these terms.This statement should be included with any information or report disclosed to the public under the freedom of information act.Any required fields that are unpopulated are blank because the information is currently unknown or unavailable.A good faith effort will be made to obtain the applicable information relevant to the report.If information is provided in the future, a supplemental report will be issued.
 
Event Description
Additional information received reported that four patients had adjustable valves.The healthcare professional believed there were no adverse events.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
STRATA®
Type of Device
SHUNT, CENTRAL NERVOUS SYSTEM AND COMPONENTS
Manufacturer (Section D)
MEDTRONIC NEUROSURGERY
5290 california ave
irvine CA 92617
Manufacturer (Section G)
MEDTRONIC NEUROSURGERY
5290 california ave
irvine CA 92617
Manufacturer Contact
glen belmer
9775 toledo way
irvine, CA 92618
6122713209
MDR Report Key18553758
MDR Text Key333379116
Report Number2021898-2024-00060
Device Sequence Number1
Product Code JXG
Combination Product (y/n)N
Reporter Country CodeUS
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Literature,Health Professional
Reporter Occupation Physician
Type of Report Initial,Followup
Report Date 01/29/2024
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received01/22/2024
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Device Operator Health Professional
Device Model NumberUNKNOWN-S
Device Catalogue NumberUNKNOWN-S
Device Lot NumberUNKNOWN
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Date Manufacturer Received01/26/2024
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
Patient Outcome(s) Other;
-
-