Model Number 801188
Device Problem Calibration Problem (2890)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Date 01/11/2024
Event Type  malfunction  
Manufacturer Narrative
The fsr replaced the oxygen (o2) sensor and the issue remained.He replaced the epgs.The unit operated to the manufacturer's specifications.During laboratory evaluation, the product surveillance technician (pst) connected the epgs to lab use only (luo) testing equipment.The epgs failed calibration.The o2 sensor was allowed to equilibrate to ambient oxygen in the room and the expected output was 9 - 13 millivolts (mv) but the sensor measured 8.8 mv.The o2 sensor was replaced with a luo o2 sensor which measured 11.3 mv in ambient air.Calibration was successful and the epgs maintained a steady and accurate o2 blend for an hour following calibration.It was determined the o2 sensor was reading too low and did not operate as intended.
 
Event Description
The field service representative (fsr) reported that during field installation of the device, the electronic patient gas system (epgs) failed calibration.There was no patient involvement.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ADVANCED PERFUSION SYSTEM 1
Type of Device
CONSOLE, HEART-LUNG MACHINE, CARDIOPULMONARY BYPASS-ADVANCED PERFUSION SYSTEM 1
Manufacturer (Section D)
TERUMO CARDIOVASCULAR SYSTEMS CORPORATION
6200 jackson road
ann arbor MI 48103
Manufacturer (Section G)
SAME
Manufacturer Contact
douglas patton
6200 jackson road
ann arbor, MI 48103
7346634145
MDR Report Key18646790
MDR Text Key334646490
Report Number1828100-2024-00045
Device Sequence Number1
Product Code DTQ
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
K172220
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Company Representative
Reporter Occupation Other
Type of Report Initial,Followup
Report Date 03/06/2024
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received02/05/2024
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Other
Device Model Number801188
Device Catalogue Number801188
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer01/29/2024
Is the Reporter a Health Professional? No
Was the Report Sent to FDA? No
Date Manufacturer Received02/13/2024
Was Device Evaluated by Manufacturer? Yes
Date Device Manufactured10/24/2023
Is the Device Single Use? No
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
-
-