Model Number 10390
Device Problem Adverse Event Without Identified Device or Use Problem (2993)
Patient Problems Perforation (2001); Cardiac Tamponade (2226); Pericardial Effusion (3271)
Event Date 02/05/2024
Event Type  Injury  
Event Description
It was reported that a pericardial effusion and cardiac perforation occurred.A left atrial appendage (laa) closure procedure was being performed.A baseline pre-existing pericardial effusion was seen prior to the start of the laa closure procedure via transesophageal echocardiography (tee).A watchman access system (was) was positioned and a 24mm watchman flx closure device and delivery system (wds) was inserted.After several recaptures and deployment of the closure device, the anesthesiologist noted that the pericardial effusion had increased in size.The physician performed a pericardial tap to treat the effusion removing one (1) liter of dark red fluid.It was then noted on fluoroscopy imaging, that the closure device had changed shape and position.A contrast injection of appendage was performed, and the physician noted a perforation of the laa wall had occurred.The patient was sent to surgery where the closure device was removed from the patient and a clip was placed on the laa.There were no further no patient complications reported.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
WATCHMAN FLX LEFT ATRIAL APPENDAGE CLOSURE DEVICE WITH DELIVERY SYSTEM
Type of Device
SYSTEM, APPENDAGE CLOSURE, LEFT ATRIAL
Manufacturer (Section D)
BOSTON SCIENTIFIC CORPORATION
300 boston scientific way
marlborough MA 01752
Manufacturer (Section G)
BOSTON SCIENTIFIC CORPORATION
ballybrit business park
galway
EI  
Manufacturer Contact
rachel shields
4100 hamline ave n
arden hills, MN 55112
6512422111
MDR Report Key18731423
MDR Text Key335703000
Report Number2124215-2024-09383
Device Sequence Number1
Product Code NGV
Combination Product (y/n)N
Reporter Country CodeUS
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Health Professional,Company Representative
Reporter Occupation Physician
Type of Report Initial
Report Date 02/19/2024
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received02/19/2024
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Device Operator Health Professional
Device Model Number10390
Device Catalogue Number10390
Device Lot Number0032348230
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Date Manufacturer Received02/05/2024
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Date Device Manufactured09/04/2023
Is the Device Single Use? Yes
Type of Device Usage Initial
Patient Sequence Number1
Patient Outcome(s) Required Intervention; Hospitalization;
Patient Age81 YR
Patient SexFemale
Patient RaceWhite
-
-