SMITH & NEPHEW, INC. UNKN TRIGEN INTERTAN INTERTROCH ANTEGR NAIL INSTR; ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES Back to Search Results
Catalog Number UNKNOWN
Device Problems Fracture (1260); Separation Failure (2547)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Date 01/31/2024
Event Type  malfunction  
Event Description
It was reported that during an internal fixation removal, using a meta-tan lag/comp kit 95/90, the screw was stuck too tightly to be removed, causing the tool to break.It was finally removed via a broken nail remover.It is unknown how was completed the procedure and if a delay was presented.No injury to patient was reported.
 
Manufacturer Narrative
H10: internal complaint reference: (b)(4).
 
Manufacturer Narrative
B5: describe event or problem, d1: brand name, d4: catalog number, lot#, udi di#, h6: health effect - impact code and medical device problem code.
 
Event Description
It was reported that during an internal fixation removal surgery, the nail removal tool (unkn trigen intertan intertroch antegr nail instr (b)(4)) broke when it was used to removed the meta-tan lag/comp kit 95/90 ((b)(4)), the screw was stuck too tightly to be removed.It was finally removed via a broken nail remover.The procedure was resumed, with the same device, after a significant delay.No injury to the patient was reported.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
UNKN TRIGEN INTERTAN INTERTROCH ANTEGR NAIL INSTR
Type of Device
ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES
Manufacturer (Section D)
SMITH & NEPHEW, INC.
1450 brooks rd.
memphis TN 38116
Manufacturer (Section G)
SMITH & NEPHEW, INC.
1450 brooks rd.
memphis TN 38116
Manufacturer Contact
holly topping
7000 west william cannon drive
austin, TX 78735
5123913905
MDR Report Key18744234
MDR Text Key335952535
Report Number1020279-2024-00412
Device Sequence Number1
Product Code HSB
Combination Product (y/n)N
Reporter Country CodeCH
PMA/PMN Number
K092748
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Other,Foreign,Health Professional,Company Representative
Reporter Occupation Other
Type of Report Initial,Followup,Followup
Report Date 03/11/2024
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received02/20/2024
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Catalogue NumberUNKNOWN
Device Lot NumberUNKNOWN
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? No
Date Manufacturer Received03/07/2024
Was Device Evaluated by Manufacturer? No
Date Device Manufactured03/13/2019
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Unknown
Patient Sequence Number1
-
-