Model Number N/A
Device Problem Material Rupture (1546)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Date 02/07/2024
Event Type  malfunction  
Manufacturer Narrative
Blank fields on this form indicate the information is unknown or unavailable.This report includes information known at this time.A follow-up report will be submitted should additional relevant information become available.This report is required by the fda under 21 cfr part 803 and is based on unconfirmed information submitted by others.Neither the submission of this report nor any statement contained herein is intended to be an admission that any cook device is defective or malfunctioned, that a death or serious injury occurred, nor that any cook device caused, contributed to, or is likely to cause or contribute to a death or serious injury if a malfunction occurred.
 
Event Description
It was reported that during the treatment of postpartum hemorrhage [pph], the bakri tamponade balloon catheter was was placed transvaginally approximately 5 minutes after delivery.The balloon was filled with approximately 350ml of saline when the balloon burst.The device was not exposed to metal tools that could damage the balloon.The total estimated blood loss was 580ml (280ml prior to device use; 300ml after device use).The hemorrhage was attributed to uterine atony.The procedure was successfully completed using another new device.No section of the device remained inside the patient's body.The patient did not require any additional procedures due to this occurrence.The complainant has not reported any adverse effects on the patient due to this occurrence.
 
Event Description
No additional information regarding the patient and/or event has been received since the previous medwatch report was sent.
 
Manufacturer Narrative
Blank fields on this form indicate the information is unchanged, unknown, or unavailable.Corrected information: b3 this report includes information known at this time.A follow up report will be submitted should additional relevant information become available.This report is required by the fda under 21 cfr part 803.This report is based on unconfirmed information submitted by others.Neither the submission of this report nor any statement made in it is intended to be an admission that any cook device is defective or malfunctioned; that a death or serious injury occurred; or that any cook device caused or contributed to; or is likely to cause or contribute to a death or serious injury if a malfunction occurred.
 
Manufacturer Narrative
Investigation ¿ evaluation: it was reported that during the treatment of postpartum hemorrhage [pph], the bakri tamponade balloon catheter was placed transvaginally approximately 5 minutes after delivery.The balloon was filled with approximately 350ml of saline when the balloon burst.The device was not exposed to metal tools that could damage the balloon.The total estimated blood loss was 580ml (280ml prior to device use; 300ml after device use).The hemorrhage was attributed to uterine atony.The procedure was successfully completed using another new device.No section of the device remained inside the patient's body.The patient did not require any additional procedures due to this occurrence.The complainant has not reported any adverse effects on the patient due to this occurrence.Reviews of the complaint history, device history record (dhr), instructions for use (ifu), and quality control, as well as a visual inspection of the returned device, were conducted during the investigation.The complaint device was returned to cook for evaluation.The balloon material was visually confirmed to be split almost the entire length of the balloon.A document-based investigation evaluation was performed.A review of the device master record (dmr) concluded that sufficient inspection activities are in place to identify this failure mode prior to distribution.A review of the dhr for the reported complaint device lot revealed no recorded non-conformances relevant to the failure mode.A database search identified one other complaint associated with the reported device lot.Review of the device history record, complaint history, quality control documents, and device failure analysis does not indicate that the device was manufactured out of specification and does not suggest items in the lot or similar devices in the field or in house are nonconforming.Cook also reviewed product labeling.The product ifu, t_j-sosr_rev4 "bakri postpartum balloon," provides the following information to the user related to the reported failure mode: how supplied: "upon removal from the package, inspect the product to ensure no damage has occurred." based on the information provided, inspection of the returned device, and the results of the investigation, a definitive cause of the event could not be determined.The appropriate personnel have been notified.Cook will continue to monitor for similar complaints.Per the risk assessment no further action is required.This report is required by the fda under 21 cfr part 803 and is based on unconfirmed information submitted by others.Neither the submission of this report nor any statement contained herein is intended to be an admission that any cook device is defective or malfunctioned, that a death or serious injury occurred, nor that any cook device caused, contributed to, or is likely to cause or contribute to a death or serious injury if a malfunction occurred.
 
Event Description
No additional information regarding the patient and/or event has been received since the previous medwatch report was sent.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
BAKRI TAMPONADE BALLOON CATHETER
Type of Device
OQY INTRAUTERINE BALLOON
Manufacturer (Section D)
COOK INC
750 daniels way
bloomington IN 47404
Manufacturer (Section G)
COOK INC
750 daniels way
bloomington IN 47404
Manufacturer Contact
jason crouch
750 daniels way
bloomington, IN 47404
8123392235
MDR Report Key18823690
MDR Text Key336878048
Report Number1820334-2024-00289
Device Sequence Number1
Product Code OQY
UDI-Device Identifier10827002306735
UDI-Public(01)10827002306735(17)251219(10)15129328
Combination Product (y/n)N
PMA/PMN Number
K170622
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Other,Foreign,User Facility,Distributor
Reporter Occupation Other
Type of Report Initial,Followup,Followup
Report Date 04/03/2024
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received03/03/2024
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Model NumberN/A
Device Catalogue NumberJ-SOS-100500
Device Lot Number15129328
Was Device Available for Evaluation? Yes
Is the Reporter a Health Professional? No
Date Manufacturer Received03/08/2024
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Date Device Manufactured12/19/2022
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
Patient SexFemale
-
-