MAUDE Adverse Event Report: MEDTRONIC PUERTO RICO OPERATIONS CO. PARADIGM REAL-TIME REVEL INSULIN INFUSION PUMP MMT-723NAS; PUMP, INFUSION, INSULIN, TO BE USED WITH INVASIVE GLUCOSE SENSOR

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

MEDTRONIC PUERTO RICO OPERATIONS CO. PARADIGM REAL-TIME REVEL INSULIN INFUSION PUMP MMT-723NAS; PUMP, INFUSION, INSULIN, TO BE USED WITH INVASIVE GLUCOSE SENSOR Back to Search Results
Model Number MMT-723NAS
Device Problem Adverse Event Without Identified Device or Use Problem (2993)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Date 02/10/2022
Event Type  Death  
Event Description
Information received by medtronic indicated that customer has passed away on (b)(6) 2022.Troubleshooting was performed.The cause of death was parkinson's and heart failure.The customer¿s blood glucose was unknown.The insulin pump was returned for analysis.
 
Manufacturer Narrative
This mdr related to the puerto rico manufacturing site has been assigned a medwatch number from the medtronic minimed northridge site, per variance 5.A complete analysis and testing of the insulin pump showed that it was functioning properly and passed all functional testing.After testing it was concluded that the device operated within specifications.S/w 3.0b.The customer passed away on (b)(6) 2022.The pump passed the functional test, including the displacement test, rewind test, basic occlusion test, occlusion test, prime/a33 test, excessive no delivery test and dat at 0.0874 inches.The stop (idle) current and run current measurement tests are within specification.The pump also passed self test, off no power alarm test and a21 error test.The following were noted during visual inspection: minor scratched display window, cracked battery tube threads and cracked reservoir tube lip.The pump did not have a battery installed when received.No damage noted on the original battery cap.The test p-cap and reservoir does lock in place in the reservoir compartment.History download was successful using thds and carelink upload was successful.Please see below when reviewing the history download file.The pump was stored for an extended period without a battery.The pump was able to download the pump history file, but it was corrupted.There was multiple a47 alarm in the pump history due to corrupted history file.Unable to perform the history review 1 week prior to the event date 10-feb-2022 in the pump history file due to no data available.Unable to verify bolus delivery, source of boluses delivered, daily insulin total and any alarms/suspends for event date 10-feb-2022 in the pump history file due to no data available.Unable to perform the history review 1 week prior to the event date 10-feb-2022 in the pump history file due to no data available.The pump passed the functional testing.A47 confirmed.Medtronic, inc.(medtronic) is submitting this report to comply with 21 c.F.R.Part 803, the medical device reporting regulation.This report is based upon information obtained by medtronic, which the company may not have been able to fully investigate or verify prior to the date the report was required by the fda.Medtronic has made reasonable efforts to obtain more complete information in the time allotted and has provided as much information as is available to the company as of the submission date this report.This report does not constitute an admission or a conclusion by fda, medtronic, or its employees that the device, medtronic, or its employees caused or contributed to the event described in the report.In particular, this report does not constitute an admission by anyone that the product described in this report has any "defects" or has "malfunctioned".These words are included in the fda 3500a form and are fixed items for selection created by the fda, to categorize the type of event solely for the purpose of reporting pursuant to part 803.Medtronic objects to the use of these words and others like it because of the lack of definition and the connotations implied by these terms.This statement should be included with any information or report disclosed to the public under the freedom of information act.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
PARADIGM REAL-TIME REVEL INSULIN INFUSION PUMP MMT-723NAS
Type of Device
PUMP, INFUSION, INSULIN, TO BE USED WITH INVASIVE GLUCOSE SENSOR
Manufacturer (Section D)
MEDTRONIC PUERTO RICO OPERATIONS CO.
ceiba norte ind. park #50 road
juncos 00777 -386
*  00777-3869
Manufacturer (Section G)
MEDTRONIC PUERTO RICO OPERATIONS CO.
ceiba norte ind. park #50 road
juncos 00777 -386
*   00777-3869
Manufacturer Contact
lusine boyadzhyan
ceiba norte ind. park #50 road
juncos 00777--386
*   00777-3869
MDR Report Key18824333
MDR Text Key336731456
Report Number2032227-2024-135473
Device Sequence Number1
Product Code OYC
UDI-Device Identifier000000643169693814
UDI-Public(01)000000643169693814
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
P150019
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Consumer
Reporter Occupation Non-Healthcare Professional
Type of Report Initial
Report Date 03/04/2024
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received03/04/2024
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Device Operator Lay User/Patient
Device Model NumberMMT-723NAS
Device Catalogue NumberMMT-723NAS
Device Lot NumberB6723NASJ
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer02/09/2024
Date Manufacturer Received02/16/2024
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Date Device Manufactured05/23/2018
Is the Device Single Use? No
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage A
Patient Sequence Number1
Patient Outcome(s) Death;
Patient Age81 YR
Patient SexMale
Patient Weight68 KG
-
-