BAXTER HEALTHCARE CORPORATION INTERMATE; PUMP, INFUSION Back to Search Results
Catalog Number 2C2122K
Device Problem Fluid/Blood Leak (1250)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Type  malfunction  
Event Description
It was reported that a large volume intermate leaked during preparation.The device contained 0.9% sodium chloride (nacl).There was no patient involvement.No additional information is available.
 
Manufacturer Narrative
Should additional relevant information become available, a supplemental report will be submitted.
 
Manufacturer Narrative
Additional information: d9, h3, h4, h6, and h10.H4: the lot was manufactured between june 21-23, 2023.H10: the device was received for evaluation.During fill, evidence of leak was observed coming out at the solvent-bonded junction of the tubing and stressmember near the fill port area.The tubing outer diameter and the stressmember inner diameter were found to be within specification.However, the tubing insertion depth was found to be inadequate (not deep enough) and therefore had caused the slow leak.Inadequate tubing insertion depth was related to manufacturing.The reported condition was verified.The cause of the reported condition was a manufacturing issue.A batch review was conducted and there were no deviations found related to this reported condition during the manufacture of this lot.Should additional relevant information become available, a supplemental report will be submitted.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
INTERMATE
Type of Device
PUMP, INFUSION
Manufacturer (Section D)
BAXTER HEALTHCARE CORPORATION
deerfield IL
Manufacturer (Section G)
BAXTER HEALTHCARE - IRVINE
17511 armstrong avenue
building 3
irvine CA 92614
Manufacturer Contact
25212 w. illinois route 120
round lake, IL 60073
2242702068
MDR Report Key18844963
MDR Text Key336966997
Report Number1416980-2024-00949
Device Sequence Number1
Product Code FRN
UDI-Device Identifier00085412487892
UDI-Public(01)00085412487892
Combination Product (y/n)N
Reporter Country CodeGM
PMA/PMN Number
NA
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Foreign,Health Professional,Company Representative
Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup
Report Date 04/09/2024
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received03/06/2024
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Other
Device Catalogue Number2C2122K
Device Lot Number23F030
Was Device Available for Evaluation? Device Returned to Manufacturer
Is the Reporter a Health Professional? Yes
Date Manufacturer Received03/18/2024
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
-
-