BECTON DICKINSON & CO. (SPARKS) BD PHOENIX¿ M50 AUTOMATED MICROBIOLOGY SYSTEM; SYSTEM, TEST, AUTOMATED ANTIMICROBIAL SUSCEPTIBILITY, SHORT INCUBATION Back to Search Results
Catalog Number 443624
Device Problem Incorrect, Inadequate or Imprecise Result or Readings (1535)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Date 02/12/2024
Event Type  malfunction  
Manufacturer Narrative
H.3.A device evaluation is anticipated but has not yet begun.Upon completion of the investigation, a supplemental report will be filed.
 
Event Description
It was reported when using the bd phoenix¿ m50 automated microbiology system, escherichia coli was misidentified as either citrobacter farmeri or enterobacter cloacae in an unspecified number of patient samples.There was no report of patient impact.
 
Event Description
It was reported when using the bd phoenix¿ m50 automated microbiology system, escherichia coli was misidentified as either citrobacter farmeri or enterobacter cloacae in an unspecified number of patient samples.There was no report of patient impact.
 
Manufacturer Narrative
Investigation summary: a results failure was reported on a phoenix m50 instrument.The customer reported erroneous identification of a microorganism.A field service engineer (fse) arrived onsite to troubleshoot the instrument.The fse found the instrument to be error free and functioning as expected.The fse performed a decontamination of the equipment, verified the temperature is in range, verified the electrical outlets and voltage is adequate, performed a software update, cleaned normalizers, lenses, light source boards.The light source boards were adjusted, and the normalizer cv was performed and acceptable.The instrument was returned to the customer in working order.The root cause of the failure is not known.This is an unconfirmed failure of a bd product.No samples were expected to be received as part of this complaint, and therefore no samples were returned, and no returned material investigation could occur.Dhr review is not required for this complaint as this complaint does not allege an early life failure or failure at installation and the configuration has changed since release from manufacturing due to service repairs/pms.Service history for this instrument was reviewed and revealed case #'s (b)(4) related to this failure mode.Bd quality will continue to monitor for trends associated with the failure mode described in this complaint.No new risks or hazards, or changes to existing risks/hazards, were identified as a result of this complaint.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
BD PHOENIX¿ M50 AUTOMATED MICROBIOLOGY SYSTEM
Type of Device
SYSTEM, TEST, AUTOMATED ANTIMICROBIAL SUSCEPTIBILITY, SHORT INCUBATION
Manufacturer (Section D)
BECTON DICKINSON & CO. (SPARKS)
7 loveton circle
sparks MD 21152
Manufacturer (Section G)
BECTON, DICKINSON & CO. (SPARKS)
7 loveton circle
sparks MD 21152
Manufacturer Contact
jo doyka
7 loveton circle
sparks, MD 21152
4103164000
MDR Report Key18846082
MDR Text Key337435527
Report Number1119779-2024-00182
Device Sequence Number1
Product Code LON
UDI-Device Identifier00382904436247
UDI-Public(01)00382904436247
Combination Product (y/n)N
Reporter Country CodeCO
PMA/PMN Number
K131331
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Other,Foreign,User Facility
Reporter Occupation Other Health Care Professional
Type of Report Initial
Report Date 02/22/2024
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received03/06/2024
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Other
Device Catalogue Number443624
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Date Manufacturer Received02/12/2024
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Date Device Manufactured11/04/2021
Is the Device Single Use? No
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial