Model Number 37612 |
Device Problems
Failure to Deliver Energy (1211); Charging Problem (2892); Adverse Event Without Identified Device or Use Problem (2993)
|
Patient Problem
No Clinical Signs, Symptoms or Conditions (4582)
|
Event Date 06/11/2021 |
Event Type
malfunction
|
Manufacturer Narrative
|
Continuation of d10: product id 37761 serial (b)(6): product type recharger section d information references the main component of the system.Other relevant device(s) are: product id: 37761, serial (b)(6) : analysis of the 37761 desktop charger (s/n (b)(6) revealed that cable assembly was replaced due to damaged pins inside the connector.This regulatory report is being submitted as part of a retrospective review as part of remediation plan 411.Medtronic is submitting this report to comply with fda reporting regulations under 21 cfr parts 4 and 803.This report is based upon information obtained by medtronic, which the company may not have been able to fully investigate or verify prior to the date the report was required by the fda.Medtronic has made reasonable efforts to obtain more complete information and has provided as much relevant information as is available to the company as of the submission date of this report.This report does not constitute an admission or a conclusion by fda, medtronic, or its employees that the device, medtronic, or its employee caused or contributed to the event described in the report.In particular, this report does not constitute an admission by anyone that the product described in this report has any ¿defects¿ or has ¿malfunctioned¿.These words are included in the fda 3500a form and are fixed items for selection created by the fda to categorize the type of event solely for the purpose of regulatory reporting.Medtronic objects to the use of these words and others like them because of the lack of definition and the connotations implied by these terms.This statement should be included with any information or report disclosed to the public under the freedom of information act.Any required fields that are unpopulated are blank because the information is currently unknown or unavailable.A good faith effort will be made to obtain the applicable information relevant to the report.If information is provided in the future, a supplemental report will be issued.
|
|
Event Description
|
Information was received from a consumer who reported their recharger suddenly stopped taking a charge from the desktop charger (dtc).The patient stated that the dtc was securely connected to the recharger, but the recharger display would only show "a cord with a plug at the end." the patient stated that their ins ended up turning off because they were unable to charge it.The patient had to see their managing healthcare provider (hcp) today because the ins was turned off, but the hcp was unable to assist the patient.A rep advised the patient to call the manufacturer to request a recharger replacement.The circumstances that led to the reported issue were asked but unknown.During the call, the patient inspected the dtc and recharger connector port, but no damage was found.However, the patient did notice that the recharger antenna cord was damaged.The patient did not know when they first noticed that the recharger antenna cord was damaged.The patient confirmed that the power indicator light was green on the ac power supply.
|
|
Search Alerts/Recalls
|
|
|