Catalog Number UNKNOWN POWER PORT
Device Problems Fluid/Blood Leak (1250); Fracture (1260); Deformation Due to Compressive Stress (2889)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Date 02/14/2024
Event Type  malfunction  
Manufacturer Narrative
H10: as the lot number for the device was not provided, a review of the device history records could not be performed.The return of the sample is pending.However, a photo and an image were provided for review.The investigation of the reported event is currently underway.H11: section a through f ¿ the information provided by bd represents all the known information at this time.Despite good faith efforts to obtain additional information, the complainant/reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.H3 other text : device pending return.
 
Event Description
It was reported that approximately six months post a port placement, the catheter was allegedly found to be cracked under imaging and pinched off near subclavian area of the patient over routine movement of the patient.It was further reported that the catheter allegedly had leak.Reportedly, the catheter allegedly kinked in the subclavian area.There was no reported patient injury.
 
Manufacturer Narrative
H10: manufacturing review: a manufacturing review was not requested as the lot number reported is unknown.Investigation summary: one powerport mri isp implantable port and a catheter was returned for evaluation.In addition to the returned physical sample, one electronic photo and image was provided for review.The photo shows a parallel split on the center portion of the catheter.The image depicts the device introduced via a left subclavian venous access and extravasation of infused contrast is seen from an irregular segment of catheter in the midclavicular region.A complete circumferential break was noted to the proximal end of the catheter returned.Catheter wear was observed throughout the center portion of the catheter.Multiple parallel splits were noted on the catheter border approximately 1.2cm, 2.8cm and 11.7cm from the proximal end of the catheter.Upon infusion, leaks were observed from the parallel splits on the catheter.Aspiration was attempted and was unsuccessful.Therefore the investigation is confirmed for the reported fracture, deformation and fluid leak issue.The definitive root cause for the reported event could not be determined based upon available information.Labeling review: as the reported event did not allege a labeling or use related issue, a labeling review is not required.H11: section a through f ¿ the information provided by bd represents all the known information at this time.Despite good faith efforts to obtain additional information, the complainant/reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.
 
Event Description
It was reported that approximately six months post a port placement, the catheter was allegedly found to be cracked under imaging and pinched off near subclavian area of the patient over routine movement of the patient.It was further reported that the catheter allegedly had leak.Reportedly, the catheter allegedly kinked in the subclavian area.There was no reported patient injury.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
UNKNOWN POWER PORT
Type of Device
PORT & CATHETER, IMPLANTED, SUBCUTANEOUS, INTRAVASCULAR
Manufacturer (Section D)
C.R. BARD, INC. (BASD) -3006260740
605 north 5600 west
salt lake city 84116
Manufacturer (Section G)
BARD REYNOSA S.A. DE C.V. -9617592
blvd. montebello #1
parque industrial colonial
reynosa, tamaulipas 88780
MX   88780
Manufacturer Contact
brett curtice
800 w. rio salado pkwy
tempe, AZ 85281
4803032689
MDR Report Key18884383
MDR Text Key337410157
Report Number3006260740-2024-01022
Device Sequence Number1
Product Code LJT
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
UNKNOWN
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Other,Health Professional,User Facility,Company Representative
Reporter Occupation Physician
Type of Report Initial
Report Date 02/17/2024
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received03/12/2024
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Catalogue NumberUNKNOWN POWER PORT
Device Lot NumberUNKNOWN
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Date Manufacturer Received02/14/2024
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
Patient SexFemale
-
-