Catalog Number 07P89-74
Device Problem High Test Results (2457)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Date 03/05/2024
Event Type  malfunction  
Manufacturer Narrative
This report is being filed on an international product, list number 07p89-74 and there is a similar product distributed in the us, list number 7p88.An evaluation is in process.A follow-up report will be submitted when the evaluation is complete.
 
Event Description
The customer reported false elevated alinity i anti-hbs and provided the following data: the anti-hbs result was 52.82 miu/ml and repeat was 49.84 miu/ml (reference: based on the world health organization recommendation, an antihbs concentration = 10 miu/ml is regarded as being protective) the customer tested the sample on the maccura platform, and the result was negative (no value provided); the colloidal gold result was negative.Additional laboratory information: hbsag/hbeag/anti-hbc were positive.The customer confirmed that they are not questioning any of the additional laboratory results.Patient information: 58 year-old man, clinically diagnosed with a remote rib fracture.Per the customer the discrepant results were not reported out to the patient¿s medical provider.There was no reported impact to patient management.There was no reported impact to patient management.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ALINITY I ANTI-HBS REAGENT KIT
Type of Device
TEST, HEPATITIS B (B CORE, BE ANTIGEN, BE ANTIBODY, B CORE IGM)
Manufacturer (Section D)
ABBOTT IRELAND DIAGNOSTICS DIVISION
finisklin business park
sligo F91VY 44
EI  F91VY44
Manufacturer (Section G)
ABBOTT IRELAND DIAGNOSTICS DIVISION
finisklin business park
sligo F91VY 44
EI   F91VY44
Manufacturer Contact
nicole jenne
max-planck-ring 2
post market surveillance
wiesbaden 65205
GM   65205
6122582960
MDR Report Key18898492
MDR Text Key337621731
Report Number3008344661-2024-00035
Device Sequence Number1
Product Code LOM
Combination Product (y/n)N
Reporter Country CodeCH
PMA/PMN Number
N/A
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Foreign,Health Professional
Reporter Occupation Other Health Care Professional
Type of Report Initial
Report Date 03/13/2024
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received03/13/2024
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Catalogue Number07P89-74
Device Lot Number51253FN01
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Date Manufacturer Received03/05/2024
Was Device Evaluated by Manufacturer? No
Is the Device Single Use? No
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
Treatment
ALNTY I PROCESSING MODU, 03R65-01, (B)(6)
Patient Age58 YR
Patient SexMale
-
-