BOSTON SCIENTIFIC CORPORATION INGEVITY+; IMPLANTABLE LEAD Back to Search Results
Model Number 7842
Device Problems Failure to Capture (1081); Mechanical Problem (1384); Off-Label Use (1494); Contamination /Decontamination Problem (2895); Device Dislodged or Dislocated (2923); Positioning Problem (3009)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Date 02/27/2024
Event Type  Injury  
Event Description
It was reported that this lead exhibited loss of capture at pre-discharge check one day post implant.X-ray showed lead dislodged into main cs.Lead was then attempted in 3 different locations within left bundle branch (lbb) region but failed to advance very far in the septum.During third attempt, helix did not retract after over 60 turns, body turns and stylet jiggling.X-ray showed helix had uncoiled and appeared more like a hook.Lead was then removed with locking stylet with helix still extended with tissue.A new lead was successfully implanted.No adverse patient effects were reported.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
INGEVITY+
Type of Device
IMPLANTABLE LEAD
Manufacturer (Section D)
BOSTON SCIENTIFIC CORPORATION
4100 hamline avenue north
saint paul MN 55112
Manufacturer (Section G)
BOSTON SCIENTIFIC CORPORATION
road 698, lot no. 12
dorado PR 00646 -260
*   00646-2602
Manufacturer Contact
timothy degroot
4100 hamline avenue north
saint paul, MN 55112
6515826168
MDR Report Key18900003
MDR Text Key337617959
Report Number2124215-2024-15407
Device Sequence Number1
Product Code NVN
UDI-Device Identifier00802526604522
UDI-Public00802526604522
Combination Product (y/n)N
Reporter Country CodeUS
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Health Professional
Reporter Occupation Physician
Type of Report Initial
Report Date 03/13/2024
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received03/13/2024
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Device Operator Lay User/Patient
Device Model Number7842
Device Catalogue Number7842
Device Lot Number1282087
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Date Manufacturer Received02/27/2024
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Date Device Manufactured12/14/2023
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
Patient Outcome(s) Hospitalization; Required Intervention;
Patient Age73 YR
Patient SexMale
-
-