MAUDE Adverse Event Report: CARDINAL HEALTH SANTA CLARA MYNX CONTROL; DEVICE, HEMOSTASIS, VASCULAR

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

CARDINAL HEALTH SANTA CLARA MYNX CONTROL; DEVICE, HEMOSTASIS, VASCULAR Back to Search Results
Catalog Number MX6760
Device Problems Decrease in Pressure (1490); Material Rupture (1546)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Date 02/20/2024
Event Type  malfunction  
Manufacturer Narrative
Additional information is pending and will be submitted within 30 days upon receipt.
 
Event Description
As reported, the balloon of a 6/7f mynx control vascular closure device (vcd) ruptured during deployment.Hemostasis was achieved by manual compression for 15 minutes.There was no reported patient injury.The device was used in an interventional procedure using a retrograde approach.The deployer was mynx certified.The device was used with a 6f 12cm non-cordis sheath.The femoral artery¿s suitability was verified on angiography, including the insertion angle (30-45 degrees) of the vascular sheath introducer.The vessel diameter was verified to be greater than or equal to 5mm in diameter.There was no vessel tortuosity.There was no presence of pvd / calcium in the vicinity of the puncture site.The device was stored and prepped per the instructions for use (ifu).The balloon lost pressure while inside of the patient.There was no prior pta, stent, or vascular graft in the common femoral artery or vein.The balloon lost pressure after being pulled to the arteriotomy.The device is being returned for evaluation.
 
Manufacturer Narrative
This device is available for analysis, but the engineering report is not yet available.However, it will be submitted within 30 days upon receipt.
 
Manufacturer Narrative
As reported, the balloon of a 6f/7f mynx control vascular closure device (vcd) ruptured during deployment.Hemostasis was achieved by manual compression for 15 minutes.There was no reported patient injury.The device was used in an interventional procedure using a retrograde approach.The deployer was mynx certified.The device was used with a 6f 12cm non-cordis sheath.The femoral artery¿s suitability was verified on angiography, including the insertion angle (30-45 degrees) of the vascular sheath introducer.The vessel diameter was verified to be greater than or equal to 5mm in diameter.There was no vessel tortuosity.There was no presence of peripheral vascular disease (pvd) / calcium in the vicinity of the puncture site.The device was stored and prepped per the instructions for use (ifu).The balloon lost pressure while inside of the patient.There was no prior percutaneous transluminal angioplasty (pta), stent, or vascular graft in the common femoral artery or vein.The balloon lost pressure after being pulled to the arteriotomy.A non-sterile ¿mynx control vcd 6f/7f¿ involved in the reported complaint was returned for investigation.Visual inspection of the received device showed that button 1 and button 2 were not depressed.The syringe was received connected to the device with the stopcock observed closed; and the balloon was found fully deflated.Furthermore, a cordis procedural sheath was locked on to the device with blood noted in it.There were no damages observed to the procedural sheath.In addition, the sealant was found in its manufactured position, fully covered by the sealant sleeves and not exposed to blood.In addition, no damages were observed to sealant sleeves assembly.Per functional analysis, an inflation/deflation test was performed per the mynx control ifu.The results revealed a leak in the balloon of the returned device.Per microscopic analysis, visual inspection at high magnification revealed a longitudinal tear in the balloon of the return device.The reported event of ¿balloon-balloon loss of pressure¿ was confirmed through analysis of the returned device.However, the exact cause of the longitudinal tear found could not be conclusively determined during analysis.Based on the information available for review and product analysis, it is difficult to determine what factors may have contributed to the loss of pressure reported.However, access site vessel characteristics (although reported that there was no presence of pvd/calcium in the vicinity of the puncture site) and/or handling factors most likely contributed to the reported event since a calcified vessel, concomitant device factors (such as a stent, or vascular graft), and/or handling factors can cause this type of damage to the balloon.According to the instructions for use (ifu), which is not intended as a mitigation, ¿the safety and effectiveness of the mynx control vcd have not been established in the following patient populations: patients with clinically significant peripheral vascular disease in the vicinity of the puncture.¿ also stated in the ifu during product preparation, ¿confirm via femoral arteriogram: common femoral artery single wall puncture.Evidence of adequate flow.No evidence of significant pvd in the vicinity of the puncture.¿ additionally, the device preparation states to discard the device if the balloon does not maintain pressure.Neither the product analysis, nor the information available for review suggest that the reported failure could be related to the design or manufacturing process of the unit.Therefore, no corrective/preventative actions will be taken at this time.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
MYNX CONTROL
Type of Device
DEVICE, HEMOSTASIS, VASCULAR
Manufacturer (Section D)
CARDINAL HEALTH SANTA CLARA
5452 betsy ross drive
santa clara CA 95054
Manufacturer (Section G)
CORDIS US CORP.
14201 nw 60 avenue
miami lakes FL 33014
Manufacturer Contact
karla castro
5452 betsy ross drive
santa clara, CA 95054
7863138372
MDR Report Key18919106
MDR Text Key337855793
Report Number3004939290-2024-00121
Device Sequence Number1
Product Code MGB
UDI-Device Identifier10862028000410
UDI-Public10862028000410
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
P040044
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Health Professional,Company Representative
Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup
Report Date 04/15/2024
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received03/17/2024
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Expiration Date03/31/2024
Device Catalogue NumberMX6760
Device Lot NumberF2207504
Was Device Available for Evaluation? Device Returned to Manufacturer
Is the Reporter a Health Professional? Yes
Was the Report Sent to FDA? No
Date Manufacturer Received03/20/2024
Was Device Evaluated by Manufacturer? No
Date Device Manufactured03/17/2022
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
Treatment
ABBOTT .038 12CM 6F SHEATH.
Patient Age56 YR
Patient SexFemale
-
-