MAUDE Adverse Event Report: INTEGRA LIFESCIENCES MANSFIELD NEUROMONITOR BASIC KIT; ICP MICROSENSORS

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

INTEGRA LIFESCIENCES MANSFIELD NEUROMONITOR BASIC KIT; ICP MICROSENSORS Back to Search Results
Catalog Number 826631
Device Problem Incorrect, Inadequate or Imprecise Result or Readings (1535)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Date 02/22/2024
Event Type  Injury  
Manufacturer Narrative
An investigation has been initiated based on the reported information.Upon completion of the investigation, a follow-up report will be submitted.
 
Event Description
A physician reported that after removing a space occupying lesion caused by hemorrhage, a microsensor (id: 826631) was implanted.The initial pressure was 6-7mmhg that eventually rose to 35mmhg after 6 hours.Computed tomography (ct) scan showed no abnormality and no change in patient's condition.Therefore, the product was removed 16 hours after surgery.Patient had no signs and symptoms due to pressure change.The patient recovered.According to information provided, it is unknown product id of monitor and cable used.It is also unknown the implantation and explantation date.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
NEUROMONITOR BASIC KIT
Type of Device
ICP MICROSENSORS
Manufacturer (Section D)
INTEGRA LIFESCIENCES MANSFIELD
11 cabot boulevard
11 cabot boulevard
mansfield MA
Manufacturer (Section G)
INTEGRA LIFESCIENCES MANSFIELD
11 cabot boulevard
mansfield MA
Manufacturer Contact
vivian nelson
1100 campus drive
princeton, NJ 
6099362319
MDR Report Key18966518
MDR Text Key338434481
Report Number3013886523-2024-00077
Device Sequence Number1
Product Code GWM
Combination Product (y/n)N
PMA/PMN Number
K914479
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Foreign,Health Professional
Reporter Occupation Physician
Type of Report Initial
Report Date 03/24/2024
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received03/24/2024
Is this an Adverse Event Report? No
Is this a Product Problem Report? No
Device Operator Health Professional
Device Catalogue Number826631
Is the Reporter a Health Professional? Yes
Date Manufacturer Received03/05/2024
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Unknown
Patient Sequence Number1
Patient Age5 MO
Patient SexFemale
-
-