THORATEC CORPORATION HEARTMATE 3 LVAS IMPLANT KIT; VENTRICULAR (ASSIST) DEVICE Back to Search Results
Model Number 106524US
Device Problem Mechanical Problem (1384)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Date 03/04/2024
Event Type  malfunction  
Manufacturer Narrative
No further information was provided.A supplemental report will be submitted once the manufacturer¿s investigation is complete.
 
Event Description
It was reported that the patient was having driveline (dl) power fault alarms since the early morning.The patient went to the clinic where first the system controller and then the modular cable were exchanged with no resolution to the alarms.The patient was then sent to get an x-ray on their driveline.The customer also reported that there were no visible kinks, twists, or compromises in the pump side of the driveline.Log files were submitted for review and captured dl power b faults on (b)(6) 2024.Additional log files were submitted after the controller was exhanged.These log files captured and confirmed the dl power b faults.On (b)(6) 2024 it was reported that the latest dl data remained the same with the power b line having issues conducting current.The power a line was working fine, and this issue had not caused any interruption in pump support.On 08mar24 the external pump side of the dl was inspected and cleaned as a precaution but did not resolve the power fault events.On (b)(6) 2024 the customer inquired about a potential dl repair but decided to instead permanently silence the alarm and monitor, and consider an exchange for the patient.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
HEARTMATE 3 LVAS IMPLANT KIT
Type of Device
VENTRICULAR (ASSIST) DEVICE
Manufacturer (Section D)
THORATEC CORPORATION
6035 stoneridge drive
pleasanton CA 94588
Manufacturer (Section G)
THORATEC CORPORATION
6035 stoneridge drive
pleasanton CA 94588
Manufacturer Contact
lindsey sallese
6035 stoneridge drive
pleasanton, CA 94588
7818528207
MDR Report Key18990262
MDR Text Key339337804
Report Number2916596-2024-01475
Device Sequence Number1
Product Code DSQ
UDI-Device Identifier00813024013297
UDI-Public00813024013297
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
P160054
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Health Professional,Company Representative
Reporter Occupation Other Health Care Professional
Type of Report Initial
Report Date 03/27/2024
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received03/28/2024
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Lay User/Patient
Device Expiration Date02/23/2024
Device Model Number106524US
Device Lot Number8443332
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Was the Report Sent to FDA? No
Date Manufacturer Received03/04/2024
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Date Device Manufactured04/25/2022
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
Patient Age65 YR
Patient SexMale
Patient Weight81 KG
Patient EthnicityNon Hispanic
Patient RaceWhite
-
-