BAXTER HEALTHCARE - IRVINE INFUSOR; PUMP, INFUSION, ELASTOMERIC Back to Search Results
Catalog Number 2C1009KP
Device Problem Defective Component (2292)
Patient Problem No Patient Involvement (2645)
Event Type  malfunction  
Event Description
It was reported that nurse found the housing cap of a large volume infusor to be abnormal, before patient use.No additional information is available.
 
Manufacturer Narrative
(b)(4).The lot 13e022 was manufactured may 8, 2013 - may 9, 2013.A review of all batch record documents was performed with no issues noted during the manufacturing process.There were no deviations from standard procedure and no exceptions related to the reported condition were noted.One sample was received at the plant for evaluation.No defect was observed during visual inspection.The housing cap, clear fill-port cap, and blue winged luer cap were found to be in their normal condition.All caps fit properly to their parts.Initial evaluation didn¿t confirm the reported condition.Upon completion of baxter's investigation, a follow-up will be submitted.
 
Manufacturer Narrative
(b)(4).Should additional relevant information become available, a supplemental report will be submitted.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
INFUSOR
Type of Device
PUMP, INFUSION, ELASTOMERIC
Manufacturer (Section D)
BAXTER HEALTHCARE - IRVINE
17511 armstrong avenue, bldg 3
irvine CA 92614
Manufacturer (Section G)
BAXTER HEALTHCARE - IRVINE
17511 armstrong avenue, bldg 3
irvine CA 92614
Manufacturer Contact
christina arnt
25212 w. illinois route 120
round lake, IL 60073
2242703198
MDR Report Key3698806
MDR Text Key4235082
Report Number1416980-2014-09831
Device Sequence Number1
Product Code MEB
Combination Product (y/n)N
Reporter Country CodeKS
PMA/PMN Number
K071222
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Foreign,Health Professional,Company Representative
Reporter Occupation Nurse
Type of Report Initial,Followup
Report Date 02/28/2014
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received03/25/2014
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Expiration Date05/01/2016
Device Catalogue Number2C1009KP
Device Lot Number13E022
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer03/12/2014
Is the Reporter a Health Professional? Yes
Date Manufacturer Received04/30/2014
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Unknown
Patient Sequence Number1
-
-