Catalog Number 10379675
Device Problems Break (1069); Nonstandard Device (1420); Out-Of-Box Failure (2311)
Patient Problem No Patient Involvement (2645)
Event Date 01/06/2015
Event Type  malfunction  
Event Description
Customer reported that 2 power supplies were in pieces when they came out of the box.Customer also reported that those 2 clinitek status+ systems were arrived in mid (b)(6) 2014.There was no report of injury due to this event.
 
Manufacturer Narrative
Siemens investigated the issue and found out that both power supplies had codes which were affected by the recall ufsn 31983.Customer has been provided with urgent field safety notice and new power cords.The original equipment manufacturer (oem) of these power supplies has identified two root causes for the damaged power supply adaptors.1.The incorrect torque setting was selected by the production operator for the screws used to secure the power supply adaptor housings together.2.Mineral oil was found on the screws used to secure the housings together.The oil is used during the machining process during the production of the screws and was not removed by the screw supplier.These two root causes resulted in a combination of mechanical and chemical stress which led to the cracking of the screw pillars inside the housing top of the power supply adaptor.Siemens issued an urgent field safety notice (31983 rev.A) in september 2014 to notify all affected siemens customers.New power cords resolved the issue.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
CLINITEK STATUS+
Type of Device
CT STATUS+
Manufacturer (Section D)
SIEMENS HEALTHCARE DIAGNOSTICS
511 benedict avenue
tarrytown 10591
Manufacturer (Section G)
SIEMENS HEALTHCARE DIAGNOSTICS MANUFACTURING, LTD.
northern road
chilton industrial estate
sudbury CO10 2XQ
UK   CO10 2XQ
Manufacturer Contact
steven andberg
2 edgewater drive
norwood, MA 02062
7812693655
MDR Report Key4442700
MDR Text Key5389604
Report Number1217157-2015-00009
Device Sequence Number1
Product Code JIL
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
K091216
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type User Facility,Company Representative
Reporter Occupation Other Health Care Professional
Remedial Action Recall
Type of Report Initial
Report Date 01/06/2015
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received01/22/2015
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Other
Device Catalogue Number10379675
Was Device Available for Evaluation? Yes
Is the Reporter a Health Professional? Yes
Date Manufacturer Received01/06/2015
Was Device Evaluated by Manufacturer? Yes
Is the Device Single Use? No
Type of Device Usage Unknown
Removal/Correction Number1217157-09-22-2014-001-R