• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: PRIDE MOBILITY PRODUCTS PRIDE MOBILITY PRODUCTS; MOTORIZED THREE-WHEELED VEHICLE

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

PRIDE MOBILITY PRODUCTS PRIDE MOBILITY PRODUCTS; MOTORIZED THREE-WHEELED VEHICLE Back to Search Results
Model Number SC900 MAXIMA 3 WHEEL
Device Problems Unintended Collision (1429); Device Tipped Over (2589); Appropriate Term/Code Not Available (3191)
Patient Problems No Information (3190); No Code Available (3191)
Event Date 12/09/2015
Event Type  Injury  
Manufacturer Narrative
The device has not been made available for evaluation at this time.Should further information or the device become available for evaluation, a follow-up report will then be issued.
 
Event Description
Provider alleges unit would not stop.Consumer turned unit off and it still kept going.Consumer ran into a pole and the unit tipped over.
 
Manufacturer Narrative
The device was returned and evaluated.The alleged event could not be duplicated.
 
Event Description
Provider alleges unit would not stop.Consumer turned unit off and it still kept going.Consumer ran into a pole and the unit tipped over.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
PRIDE MOBILITY PRODUCTS
Type of Device
MOTORIZED THREE-WHEELED VEHICLE
Manufacturer (Section D)
PRIDE MOBILITY PRODUCTS
182 susquehanna ave
n/a
exeter PA 18643
Manufacturer (Section G)
N/A
n/a
n/a
n/a
Manufacturer Contact
kelly livingston
182 susquehanna ave
n/a
exeter, PA 18643
5706555574
MDR Report Key5307108
MDR Text Key33783811
Report Number2530130-2015-00128
Device Sequence Number1
Product Code INI
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
K091113
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative
Reporter Occupation Other
Type of Report Initial,Followup
Report Date 09/15/2016
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received12/17/2015
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Device Operator Lay User/Patient
Device Model NumberSC900 MAXIMA 3 WHEEL
Device Catalogue NumberN/A
Device Lot NumberN/A
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer01/07/2016
Is the Reporter a Health Professional? No
Date Manufacturer Received12/14/2015
Was Device Evaluated by Manufacturer? Yes
Date Device Manufactured04/29/2015
Is the Device Single Use? No
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Reuse
Removal/Correction NumberN/A
Patient Sequence Number1
Patient Outcome(s) Hospitalization;
-
-