Catalog Number 1011710-38
Device Problems Break (1069); Kinked (1339); Torn Material (3024)
Patient Problem No Patient Involvement (2645)
Event Date 01/11/2016
Event Type  malfunction  
Manufacturer Narrative
(b)(4).During processing of this complaint, attempts were made to obtain complete event, patient and device information.(b)(4).Evaluation summary: the device was returned for analysis with a tear in the outer member and separation of bayonet and support mandrel; however the device was still in one piece.The kink was able to be confirmed.Based on a visual inspection of the returned device, there is no indication of a product quality issue with respect to the design, manufacture, or labeling of the device.The investigation determined the reported difficulties appear to be related to circumstances of the procedure.A review of the lot history record identified no manufacturing nonconformities issued to the reported lot.Additionally, a review of the complaint history identified no other similar incidents reported from this lot.Based on the information reviewed, there is no indication of a product quality issue with respect to the design, manufacture, or labeling of the device.
 
Event Description
It was reported that a 3.5x38mm xience prime was bent or damaged and could not be used in the patient anatomy.The procedure was completed with balloon angioplasty.No additional information was provided.The returned device analysis identified a tear in the outer member and separation of bayonet and support mandrel.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
XIENCE PRIME LL EVEROLIMUS ELUTING CORONARY STENT SYSTEM
Type of Device
DRUG ELUTING CORONARY STENT SYSTEM
Manufacturer (Section D)
AV-TEMECULA-CT
abbott vascular
26531 ynez road
temecula CA 92591 4628
Manufacturer (Section G)
CLONMEL, IRELAND REG# 9616693
abbott vascular
26531 ynez road
temecula CA 92591 4628
Manufacturer Contact
connie speck
abbott vascular
26531 ynez road
temecula, CA 92591-4628
9519143996
MDR Report Key5495600
MDR Text Key40265509
Report Number2024168-2016-01522
Device Sequence Number1
Product Code NIQ
Combination Product (y/n)N
Reporter Country CodeAS
PMA/PMN Number
P110019
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,foreig
Reporter Occupation Health Professional
Remedial Action Other
Type of Report Initial
Report Date 03/11/2016
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received03/11/2016
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Expiration Date05/24/2018
Device Catalogue Number1011710-38
Device Lot Number5051941
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer02/16/2016
Is the Reporter a Health Professional? Yes
Date Manufacturer Received03/07/2016
Was Device Evaluated by Manufacturer? Yes
Date Device Manufactured05/01/2015
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
-
-