MAUDE Adverse Event Report: ETHICON ENDO-SURGERY, LLC. ULTRACISION HARMONIC ACE; INSTRUMENT, ULTRASONIC SURGICAL

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

ETHICON ENDO-SURGERY, LLC. ULTRACISION HARMONIC ACE; INSTRUMENT, ULTRASONIC SURGICAL Back to Search Results
Catalog Number ACE36J
Device Problems Device Inoperable (1663); Failure to Advance (2524); Device Displays Incorrect Message (2591)
Patient Problem No Consequences Or Impact To Patient (2199)
Event Date 01/08/2016
Event Type  malfunction  
Manufacturer Narrative
(b)(4).Date sent: 03/30/2016.Batch # m91755.The device was returned with the distal tip of the blade broken off and not returned.The remaining blade portion was scratched, and with evidence of contact with metal in or out of the operative field.This blade tip portion may have broken off of the device during transport to our analysis site.The reported complaint was for: "an error occurred and the device became not to be activated." the device was functionally tested with a generator.During functional testing on gen04 an error code 5 was displayed.A probable cause of the device not activating and displaying an error code 5 is blade damage.Probable causes of blade damage, including breakage, are external contact during pre-op or general use, blade contact with other devices, staples or clips during the procedure or using any means other than the blade wrench to attach or detach the blade.Once minor blade damage has occurred, subsequent activations may increase damage severity and result in an error code 5 or blade lockout later in the procedure.The generator system will revert to standby mode, when the audible alarm (solid tone) and visual alarm indicator appear.No incident related to the reported event was observed during the batch record review.
 
Event Description
It was reported that during a lap gastrectomy, an error occurred and the device became not to be activated in the middle of the operation.The error code was unknown.The blade tip was not broken off and no pieces fell into the patient.Another device was used to complete the case.There were no adverse consequences to the patient.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ULTRACISION HARMONIC ACE
Type of Device
INSTRUMENT, ULTRASONIC SURGICAL
Manufacturer (Section D)
ETHICON ENDO-SURGERY, LLC.
475 calle c
guaynabo PR 00969
Manufacturer (Section G)
ETHICON ENDO-SURGERY, LLC
475 calle c
guaynabo PR 00969
Manufacturer Contact
milton garrett
4545 creek road ml 120a
cincinnati, OH 45242
5133378865
MDR Report Key5535138
MDR Text Key41771158
Report Number3005075853-2016-01758
Device Sequence Number1
Product Code LFL
Combination Product (y/n)N
Reporter Country CodeJA
PMA/PMN Number
K042777
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,foreig
Reporter Occupation Other
Type of Report Initial
Report Date 01/27/2016
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received03/30/2016
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Expiration Date04/20/2020
Device Catalogue NumberACE36J
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer03/23/2016
Is the Reporter a Health Professional? No
Date Manufacturer Received03/23/2016
Was Device Evaluated by Manufacturer? Yes
Date Device Manufactured05/20/2015
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
-
-