Model Number 16402
Device Problem False Alarm (1013)
Patient Problem No Patient Involvement (2645)
Event Type  malfunction  
Manufacturer Narrative
(b)(4).
 
Event Description
The field service representative (fsr) reported that during preventive maintenance (pm) of the device, the roller pump has a problem with a diode in pump power board, causing battery back-up light to remain on.The unit was a spare roller pump.There was no patient involvement.
 
Manufacturer Narrative
The field service representative (fsr) replaced the shorting link, heat sink, cable assembly and the diodes.The unit operated to manufacturer specifications and was returned to clinical use.The suspect parts were returned to the manufacturer for further evaluation.During the laboratory evaluation, one of the two diodes mounted to the heatsink was shorted electrically.No problem was found with the other diode.If additional information becomes available on this complaint that would alter the facts and/or conclusion, a supplemental report will be filed accordingly.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
SARNS 8000 PERFUSION SYSTEM
Type of Device
PUMP, BLOOD, CARDIOPULMONARY BYPASS, ROLLER TYPE - SARNS ROLLER PUMP
Manufacturer (Section D)
TERUMO CARDIOVASCULAR SYSTEMS CORP.
6200 jackson road
ann arbor MI 48103
Manufacturer Contact
jan winder
6200 jackson road
ann arbor, MI 48103
7346634145
MDR Report Key5684953
MDR Text Key46092196
Report Number1828100-2016-00380
Device Sequence Number1
Product Code DWB
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
K915183
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative
Reporter Occupation Other
Type of Report Initial,Followup
Report Date 09/01/2016
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received05/27/2016
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Other
Device Model Number16402
Device Catalogue Number16402
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer08/11/2016
Is the Reporter a Health Professional? No
Date Manufacturer Received08/11/2016
Was Device Evaluated by Manufacturer? Yes
Date Device Manufactured01/11/2007
Is the Device Single Use? No
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Reuse
Patient Sequence Number1
-
-