MAUDE Adverse Event Report: EDWARDS LIFESCIENCES DR DISPOSABLE PRESSURE TRANSDUCER; TRANSDUCER, PRESSURE, CATHETER TIP

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

EDWARDS LIFESCIENCES DR DISPOSABLE PRESSURE TRANSDUCER; TRANSDUCER, PRESSURE, CATHETER TIP Back to Search Results
Model Number CDPUNKNOWN
Device Problem Particulates (1451)
Patient Problem No Known Impact Or Consequence To Patient (2692)
Event Date 07/11/2016
Event Type  malfunction  
Manufacturer Narrative
The device evaluation is anticipated.However the complaint could not be confirmed without the completion of the product evaluation.A supplemental report will be forthcoming with the evaluation results.
 
Event Description
It was reported that an unknown small white particulate was found inside the dpt on the yellow line during use.There were no patient complications reported.
 
Manufacturer Narrative
Per chemistry study (b)(4), the ir spectrum of the unknown white substance showed similar absorption characteristics when comparing to plyisoprene like material.
 
Manufacturer Narrative
We received one triple flothru dpt-vamp plus kit with iv set and pressure tubing.A review of the manufacturing records indicated that the product met specification at the time of release.As received in the laboratory, the white particulate was not able to be visually located.The pa (yellow) line was continuously flushed at high pressures for five minutes while flushing solution was filtered.After flushing, the particulate was not found on the filter paper.However, the particulate was found and removed from the dpt fluid path using a guidewire.The particulate stayed within the dpt fluid path during flushing.Supplemental report will be submitted pending the chemistry results.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
DISPOSABLE PRESSURE TRANSDUCER
Type of Device
TRANSDUCER, PRESSURE, CATHETER TIP
Manufacturer (Section D)
EDWARDS LIFESCIENCES DR
carretera sanchez, km 18 1/2
parque ind. de itabo
haina. san cristobal
DR 
Manufacturer (Section G)
EDWARDS LIFESCIENCES DR
carretera sanchez, km 18 1/2
parque ind. de itabo
haina. san cristobal
DR  
Manufacturer Contact
brian hurd-servin
1 edwards way
irvine, CA 92614
9492506423
MDR Report Key5841686
MDR Text Key51003264
Report Number2015691-2016-02414
Device Sequence Number1
Product Code DXO
Combination Product (y/n)N
Reporter Country CodeJA
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type foreign,health professional,o
Reporter Occupation Other
Type of Report Initial,Followup,Followup
Report Date 07/12/2016
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received08/02/2016
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Model NumberCDPUNKNOWN
Device Lot NumberHH0188MT
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer07/20/2016
Is the Reporter a Health Professional? No
Date Manufacturer Received08/22/2016
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
-
-