Model Number 3007301
Device Problem Smoking (1585)
Patient Problem No Known Impact Or Consequence To Patient (2692)
Event Date 08/12/2016
Event Type  malfunction  
Manufacturer Narrative
A follow-up report will be submitted once the investigation is completed.
 
Event Description
The following information was received from a bayer representative: a customer reported that smoke was seen coming from the base unit of the medrad® stellant ct injection system.The customer powered down the system and unplugged it from the wall.The local fire department responded to the facility and evacuated the area.No injury or adverse event was reported.
 
Manufacturer Narrative
Bayer service replaced the power supply and confirmed system functionality.Bayer product analysis received and examined the returned power supply.Visual examination confirmed damage consistent with a typical electronic fault.The power supply is centrally located within a metal electronic chassis of the base unit and is well isolated from the patient and user.Therefore, there is no injury or property damage risk were the fault to recur.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
STELLANT DUAL CT INJECTOR
Type of Device
CT INJECTION SYSTEM
Manufacturer (Section D)
BAYER MEDICAL CARE, INC.
1 bayer drive
indianola PA 15051
Manufacturer (Section G)
BAYER MEDICAL CARE, INC.
1 bayer drive
indianola PA 15051
Manufacturer Contact
diane eckert
1 bayer drive
indianola, PA 15051
7249408677
MDR Report Key5939740
MDR Text Key54763454
Report Number2520313-2016-00063
Device Sequence Number1
Product Code DXT
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
K082905
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,health
Reporter Occupation Radiologic Technologist
Type of Report Initial,Followup
Report Date 08/12/2016
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received09/09/2016
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Radiologic Technologist
Device Model Number3007301
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer08/18/2016
Is the Reporter a Health Professional? Yes
Date Manufacturer Received08/12/2016
Was Device Evaluated by Manufacturer? Yes
Date Device Manufactured11/25/2005
Is the Device Single Use? No
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Reuse
Patient Sequence Number1
-
-