MAUDE Adverse Event Report: PHILIPS MEDICAL SYSTEMS AVALON FM30 FETAL MONITOR

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

PHILIPS MEDICAL SYSTEMS AVALON FM30 FETAL MONITOR Back to Search Results
Model Number M2703A
Device Problems Incorrect Or Inadequate Test Results (2456); Device Operates Differently Than Expected (2913)
Patient Problem Death, Intrauterine Fetal (1855)
Event Date 11/29/2016
Event Type  Death  
Manufacturer Narrative
A follow-up report will be submitted upon completion of the investigation.
 
Event Description
In this case the customer reported a patient incident with a deceased fetus where it is now in question why the monitor showed a fetal heart rate but the fetus was deceased.
 
Manufacturer Narrative
The patient is a (b)(6) year-old (b)(6) female, primigravida, presenting with a pregnancy at (b)(6) with a recently diagnosed fetal demise.The patient presented to the emergency room on (b)(6) 2016 in the morning complaining of decreased fetal movement.On workup ultrasound was done revealing fetal demise.Labs were, otherwise, unremarkable on her workup.Ultrasound that was done in the radiology department revealed the fetal demise.No cardia motion.The estimated age of the fetus was (b)(6).The placenta was anterior with no previa.Cervical length was 3.1 cm.Afi was 16.2.On the patient¿s presentation to the emergency room, there was a fetal heart rate trace taken.It showed a fetal heart rate between 150s to 170s with some unusual hyper variability.No apparent decelerations looking at the fetal heart rate tracing retrospectively.The maternal heart rate was measured with a spo2 transducer and was between 80s and 90s bpm.The provided data (log files and strips) have been evaluated in the factory by a philips clinician and the product support engineer.The log files showed no fatal errors.Evaluation of the provided strips identified that the fetal heart rate presented in the trace are duplicated maternal heart rates.From a technical point of view this is not a malfunction.The algorithm measuring the fetal heart rate is designed to detect pulsations from the fetal heart.In case the fetal is already demised, the algorithm will take the next best pulsating signal which is the maternal aorta.Due to the demised fetus swinging in the anionic fluid within in the ultrasound beam, the algorithm easily might double or half the detected heart rate.This is one limitation of the auto correlation algorithm.The auto correlation algorithm can display a doubled fetal or maternal heart rate if the duration of diastole and systole are similar to each other, and if the heart rate is below 120 bpm.Doubling, usually brief, is accompanied by an abrupt switch of the trace to double the baseline value.In addition the maternal heart rate may simulate a normal fetal heart rate pattern (i.E., it may mask a fhr deceleration or fetal demise).It was found that the fetal life was not confirmed before starting patient monitoring as it is strongly recommend by philips.Fetal movement profile (fmp) annotations on a fetal trace alone may not always indicate that the fetus is alive.The body of a deceased fetus can move and cause the monitor to annotate fetal body movements.This is what the customer has seen in this case on the strips.There had been movement annotations even when the fetus was already deceased.The customer has not confirmed the fetal life before starting with patient monitoring.In case the fetus is already deceased when doing fetal monitoring the device might misinterpret the maternal heart rate obtained from the aorta as fetal heart rate.Due to the fact that deceased fetus is swimming in the anionic fluid in front of the aorta, these movements might be misinterpreted as fetal movement of a well being fetus.Thus this case falls into a usage of outside normal and expected.The results of the event investigation and device evaluation have been provided to the customer in a customer letter.There was no malfunction of the device.The device remains at the customer site.No part failed.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
AVALON FM30 FETAL MONITOR
Type of Device
FETAL MONITOR
Manufacturer (Section D)
PHILIPS MEDICAL SYSTEMS
hewlett-packard str.2
boeblingen 71034
GM  71034
Manufacturer (Section G)
PHILIPS MEDICAL SYSTEMS
3000 minuteman road
andover MA 01810
Manufacturer Contact
robert corning
hewlett-packard str.2
boeblingen 71034
GM   71034
MDR Report Key6171431
MDR Text Key62335264
Report Number9610816-2016-00314
Device Sequence Number0
Product Code HGM
Reporter Country CodeUS
PMA/PMN Number
K052795
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type user facility
Reporter Occupation Other
Type of Report Initial,Followup
Report Date 11/29/2016
2 Devices were Involved in the Event: 1   2  
1 Patient was Involved in the Event
Date FDA Received12/13/2016
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Device Operator Health Professional
Device Model NumberM2703A
Was Device Available for Evaluation? Yes
Is the Reporter a Health Professional? No
Was the Report Sent to FDA? No
Date Manufacturer Received11/29/2016
Was Device Evaluated by Manufacturer? Yes
Date Device Manufactured06/12/2015
Is the Device Single Use? No
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Reuse
Patient Sequence Number1
Patient Outcome(s) Death;
Patient Age1 DA
-
-