BOSTON SCIENTIFIC - MAPLE GROVE ELUVIA¿ DRUG-ELUTING VASCULAR STENT SYSTEM; STENT, SUPERFICIAL FEMORAL ARTERY, DRUG-ELUTING Back to Search Results
Model Number H74939295601510
Device Problems Difficult or Delayed Positioning (1157); Positioning Failure (1158)
Patient Problem No Consequences Or Impact To Patient (2199)
Event Type  malfunction  
Manufacturer Narrative
(b)(4).Device evaluated by mfr: the device has not been received for analysis.The batch number is unknown and the manufacturing records for the complaint device could not be reviewed.The most probable root cause is operational context as device performance was limited due to anatomical procedural factors.(b)(4).
 
Event Description
Same case as: 2134265-2016-11569.Partial deployment and deployment difficulties occurred.The target lesion had numerous tortuosities.It was reported that the 6x150 eluvia¿ drug-eluting vascular stent system was advanced via the "humeral" approach to the lesion.After approximately 4cm of deployment the thumbwheel stopped working and stent deployment was unable to be completed by utilizing the pull grip.The stent fractured and a piece of the stent remained inside of the patient.The portion of the stent was unable to be located.A second 6x150 eluvia stent was advanced by the "cross-over" approach.Deployment was initiated and after approximately 4cm the thumbwheel stopped working and deployment was unable to be completed by utilizing the pull grip.The entire device was removed without any negative consequences to the patient.There were no further patient complications required and the patient's status is fine.This product is only ous approved but it is similar to an approved us device.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ELUVIA¿ DRUG-ELUTING VASCULAR STENT SYSTEM
Type of Device
STENT, SUPERFICIAL FEMORAL ARTERY, DRUG-ELUTING
Manufacturer (Section D)
BOSTON SCIENTIFIC - MAPLE GROVE
one scimed place
maple grove MN 55311
Manufacturer Contact
sonali arangil
one scimed place
maple grove, MN 55311
7634941700
MDR Report Key6181727
MDR Text Key62679471
Report Number2134265-2016-11568
Device Sequence Number1
Product Code NIU
Combination Product (y/n)N
Reporter Country CodeFR
PMA/PMN Number
SIMILAR
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,foreig
Reporter Occupation Physician
Type of Report Initial
Report Date 11/25/2016
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received12/16/2016
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Model NumberH74939295601510
Device Catalogue Number39295-60151
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Date Manufacturer Received11/25/2016
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
-
-