• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: FISHER & PAYKEL HEALTHCARE LTD ADULT NASAL INTERFACE; CAT

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

FISHER & PAYKEL HEALTHCARE LTD ADULT NASAL INTERFACE; CAT Back to Search Results
Model Number OPT944
Device Problem Device Issue (2379)
Patient Problem No Consequences Or Impact To Patient (2199)
Event Type  malfunction  
Manufacturer Narrative
(b)(4).The complaint cannula is currently en route to fisher & paykel healthcare for evaluation.We will provide a follow up report upon completion of our investigation.
 
Event Description
A hospital in (b)(6) reported that the tubing of an opt944 nasal cannula detached from the distal connector that attaches to the breathing circuit.No patient consequence was reported.
 
Manufacturer Narrative
(b)(4).The opt944 interface is used to deliver humidified oxygen to patients and consists of a lightweight delivery tube connected to a rigid plastic base and soft nasal prongs (nasal interface).The interface is held in place by a head strap and features a head strap clip which works in tandem with the tubing clip (attaches to the patient's clothing/bedding) to support the weight of the circuit and prevent the cannula being dislodged.Method: the complaint cannula was returned to fisher & paykel healthcare, however it was an opt946 cannula, not an opt944.The opt944 is size medium, whereas the opt946 is size large.The complaint device was visually inspected.Results: visual inspection of the returned cannula revealed that the tubing was detached from the swivel connector.The swivel was found to be operational.Conclusion: the observed damage to the complaint cannula is most likely the result of pulling on the cannula tubing with undue force.All optiflow interfaces are inspected during production for visual defects including cracks, tears, inclusions, discolouration and stretching or deformation.Any product that fails the visual inspection is disposed of.The setup instructions in the user instructions which accompany the opt900 series nasal cannula include the following steps: - ensure head strap clip is attached, to prevent cannula from being pulled out of the nares.- cannula can become unattached if not used with the head strap clip.- attach tubing clip to clothing/bedding to prevent cannula from pulling off face.The user instructions also contain the following warnings/cautions: - do not crush or stretch tube, to prevent loss of therapy.- failure to use the set-up described above can compromise performance and affect patient safety.Our optiflow production team has been notified of this failure.They have carried out an internal investigation of the manufacturing process and production staff have received additional training to ensure they are following the correct assembly procedure.
 
Event Description
A hospital in (b)(6) reported that the tubing of an opt944 nasal cannula detached from the distal connector that attaches to the breathing circuit.No patient consequence was reported.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ADULT NASAL INTERFACE
Type of Device
CAT
Manufacturer (Section D)
FISHER & PAYKEL HEALTHCARE LTD
15 maurice paykel place
east tamaki
auckland, 2013
NZ  2013
Manufacturer (Section G)
FISHER & PAYKEL HEALTHCARE LTD
15 maurice paykel place
east tamaki
auckland, 2013
NZ   2013
Manufacturer Contact
jon stevens
173 technology drive
suite 100
irvine, CA 92618
9194534000
MDR Report Key6334807
MDR Text Key67542079
Report Number9611451-2017-00100
Device Sequence Number1
Product Code CAT
Combination Product (y/n)N
Reporter Country CodeUS
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,health
Reporter Occupation Respiratory Therapist
Type of Report Initial,Followup
Report Date 01/19/2017
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received02/15/2017
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Model NumberOPT944
Device Catalogue NumberOPT944
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer02/23/2017
Is the Reporter a Health Professional? Yes
Date Manufacturer Received01/19/2017
Was Device Evaluated by Manufacturer? Yes
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
-
-